NOTE
In order to carry out Performance Checks using the Function Checker, it is necessary to be familiar
with the correct operation of the C.Scope Locator to be tested.
NOTE
Only use the Function Checker in an area that has been scanned and found to be suitable for use,
as described in the ‘Selecting a suitable location’ section on page 8.
These tests should NOT be carried out in the close vicinity of any active Signal Generators, Transmitters or Sondes.
1. Place the Function Checker on the ground with the Accessory Tray securely clipped to
the underside of the Function Checker.
2. Switch ON the Function Checker. Check the Battery Condition Indicator in the bottom
left hand corner of the Function Checker display. If there is only one segment or no segments
of the indicator filled in then the batteries must be replaced before the Function Checker
can be used.
3. Position the Locator alongside the Function Checker with the base of the Locator touching
the ground and one of the Function Checker Accessory Tray Retaining Clips.
NOTE
The Locator can be placed either side of the Function Checker but must be touching the side and held vertically.
If the Locator is transferred from one side of the Function Checker to the other the same visual response should occur
on the Locator. This can be a good indication that there are no interfering signals from nearby sources. If the Locator
responses are not the same then try testing in a different location.
Performance checking
MXL
Battery
Levels OK
Replace
Batteries
Battery Indicator
30
Содержание Function Checker
Страница 1: ...Instruction Manual Function Checker PRECISION PIPE AND CABLE LOCATION...
Страница 13: ...Performance Checks C Scope Locators 13...
Страница 42: ...42 Performance Checks C Scope Signal Generators and Transmitters...
Страница 68: ...68 Performance Checks C Scope Signal Generator pre 2003 model...