T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
95
8
Electrical Fittings
8.6.4
12 V Main Switch
The 12 V main switch (Fig. 90,5) switches the 12 V power supply to the living area on and off.
Exception: heating, basic light (lighting in the entrance area) entrance step and spare 4 on the trans-
former/rectifier are always ready to operate.
³
Press rocker switch (Fig. 90,5) up
: the 12 V living area power supply is switched on.
Green indicator lamp (Fig. 90,4) comes on.
³
Press rocker switch (Fig. 90,5) down
: the 12 V living area power supply is switched off. In-
dicator lamp (Fig. 90,4) goes off.
8.6.5
Indicator Lamp for the 12 V Power Supply
The indicator lamp (Fig. 90,4) lights up when the 12 V main switch (Fig. 90,5) is switched on.
8.6.6
230 V Power Indicator Lamp
The yellow 230 V indicator lamp (Fig. 90,6) lights up whenever line voltage is available at the trans-
former/rectifier input.
8.6.7
Switch for Water Pump
³
Press rocker switch (Fig. 90,7) up
: the water supply is ON.
³
Press rocker switch (Fig. 90,7) down
: the water supply OFF.
8.7
Panel (E-Display)
Duty of the panel
z
Reading all condition data (e. g. fill levels, battery state)
z
Switching four separate circuits on/off (e. g. exterior lighting, seating group lights, bed lights and
water pump)
z
Control of four separate circuits via an interval timer
V
To prevent unnecessary discharging of the living area batteries, turn off the 12 V main
switch whenever you leave the vehicle.
V
Appliances such as the safety/drainage valve, charger, solar regulator and panel con-
sume approx. 20 mA to 65 mA of electricity from the battery capacity, even when the
main switch is turned off. Therefore, you should switch the battery cut-off switch on the
transformer/rectifier to "Batterie Aus" (battery OFF) when the motorhome is not used
for a long period of time.
V
If the motorhome is not connected to the 230 V power supply, the water pump’s power
supply will switch off if it is not used over a longer period of time. The pump relay uses
around 4 Ah current each day.
Содержание T-585
Страница 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Страница 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Страница 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Страница 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Страница 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Страница 105: ...T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN 105 8 Electrical Fittings Fig 102 Circuit diagram interior E Box ...
Страница 106: ...8 106 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings Fig 103 Circuit diagram panel IT 991 ...
Страница 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Страница 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Страница 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Страница 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Страница 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Страница 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Страница 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Страница 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...