T-Modell - 04/05 - Ausgabe 08/04 - 201804286 - BUE-0006-04EN
Sanitary Fittings
³
Keep the taps op until the water flowing out of the taps has no bubbles in it. This is the only way
to ensure that the boiler is also full of water.
³
Set all water taps to "Cold" and leave them on. This will fill the cold water pipes with water.
³
Keep the taps op until the water flowing out of the taps has no bubbles in it.
³
Close all water taps.
³
Close the fresh water filler neck.
³
Check that the cap on the water tank is not leaking.
10.4
Emptying the Water System
To empty and ventilate the water system, proceed as follows. This will avoid frost damage:
³
Park the motorhome so that it is level.
³
Set the water pump on the panel to "Off".
³
Switch off the 12 V power supply at the panel.
³
Shut off the boiler (see section 9.3).
³
Open the drain cocks. To do this, position the rocking lever (Fig. 134,1) vertically.
³
Open the safety/drainage valve (Trumatic C boiler only). Push the pull switch (Fig. 133,1) down.
³
Unscrew the cap of the water tank.
³
Open the water tank drain (see section 10.2.4).
³
Open all water taps and set to the central position.
³
Hang the shower handset up in the shower position.
³
Hold the water pump up until the water pipes are completely empty.
³
Check whether the water tank is completely empty.
³
Blow out the remaining water in the water pipes (max. 0.5 bar).
³
Empty the waste water tank. Take note of the environmental tips in this chapter.
³
Empty Thetford cassette. Take note of the environmental tips in this chapter.
³
Clean the water tank and then rinse it out thoroughly.
³
Let the water system dry for as long as possible.
³
After emptying, leave all water taps on in the central position.
³
Leave all drain cocks open.
Position of the drain cocks and safety/drainage valve
See chapter 16.
V
If the vehicle is not heated when there is risk of frost, empty the entire water system.
Leave the water taps on in central position. Leave all drain cocks open. This will avoid
frost damage to appliances and to the vehicle.
V
The Truma system (heater/boiler) has an electric safety/drainage valve and a drain
cock (yellow) for emptying.
V
The Alde system (heater/boiler) has two drain cocks (yellow) for emptying.
Содержание T-585
Страница 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Страница 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Страница 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Страница 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Страница 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Страница 105: ...T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN 105 8 Electrical Fittings Fig 102 Circuit diagram interior E Box ...
Страница 106: ...8 106 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings Fig 103 Circuit diagram panel IT 991 ...
Страница 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Страница 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Страница 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Страница 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Страница 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Страница 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Страница 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Страница 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...