Electrical Fittings
8.5.1
Main Switch
The main switch (Fig. 89,4) disconnects all the living area 12 V appliances, even the safety/drainage
valve. This prevents the living area battery from slowly discharging if the motorhome is not used for
a longer period of time (e. g. temporary lay-up).
The batteries can still be charged by the transformer/rectifier when the main switch is turned off.
³
Press main switch up to "I": battery ON.
³
Press main switch down to "O": battery OFF.
8.5.2
Battery Monitor
The battery monitor in the transformer/rectifier monitors the voltage in the living area battery.
If the battery voltage falls below 10.6 V, the battery monitor switches off all of the 12 V appliances,
excluding the safety/drainage valve.
An AES refrigerator will automatically switch to gas operation.
³
Switch off all appliances that are not absolutely essential at the appropriate switch.
³
If necessary, use the rotary knob (Fig. 91,2) to switch the 12 V power supply back on for a short
while. This is only possible, however, when the battery voltage is above 11 V. If the voltage is
below this level, the 12 V power supply cannot be switched on again until the living area battery
has been recharged.
8.5.3
Charging the Battery
If the motorhome is connected to the 230 V power supply, the living area battery is charged by the
transformer/rectifier. The transformer/rectifier charges the starter battery with a float charge only.
8.5.4
Battery Selector Switch
V
When the main switch is turned off, the safety/drainage valve opens. The water flows
out of the boiler.
V
When the main switch is turned back on, or once the living area battery terminals have
been disconnected and then reconnected, the 12 V power supply must be briefly
switched back on at the panel. This will reactivate the basic light (lighting in the en-
trance area - if fitted), entrance step, heater and spare 4.
V
You must fully recharge a discharged living area battery as soon as possible.
V
If the battery selector switch is wrongly set, there is a danger that oxyhydrogen gas
could build up and explode.
V
Incorrect setting of the battery selector switch damages the living area battery.
V
The factory settings of the battery selector switch (Fig. 89,2) must not be changed.
V
Further information can be obtained from the separate instruction manual "E-Control".
Содержание T-585
Страница 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Страница 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Страница 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Страница 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Страница 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Страница 105: ...T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN 105 8 Electrical Fittings Fig 102 Circuit diagram interior E Box ...
Страница 106: ...8 106 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings Fig 103 Circuit diagram panel IT 991 ...
Страница 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Страница 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Страница 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Страница 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Страница 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Страница 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Страница 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Страница 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...