Appliances
Safety/drainage valve boiler
The boiler is equipped with a safety/drainage
valve (Fig. 117). The safety/drainage valve pre-
vents water in the boiler from freezing, when
there is frost and the heater is not switched on.
Fig. 117 Safety/drainage valve of the boiler
The voltage supply for the heater/boiler and the safety/drainage valve cannot be interrupted by the
12 V main switch or the rotary knob on the E-display. When there is a fault, the red indicator lamp
(Fig. 106,8) on the operating unit for Trumatic C heater/boiler illuminates (see chapter 14).
Filling with water:
³
Close the safety/drainage valve. Pull the pull switch (Fig. 117,1) up.
³
Switch the 12 V power supply on.
³
Open all water taps and set to "Warm" position. Water pump is pumping water into the boiler.
³
Leave all water taps on until water is free of bubbles. Boiler is filled with water.
³
Close the water taps.
V
When the safety/drainage valve is
closed a small electrical power
flows which puts an extra load on
the battery of the living area.
Therefore, a daily check of the
battery voltage panel is recom-
mended. If the battery voltage
drops to below 10.8 V the function
of the safety/drainage valve can
no longer be guaranteed.
V
When the motorhome is not used
for a long period of time, open the
safety/drainage valve and drain
the boiler.
V
At temperatures of less than 8 °C the safety/drainage valve opens automatically.
Therefore, you must turn on the living area heater and wait until the living area temper-
ature exceeds 8 °C before you fill the boiler.
V
The water pump and the water fittings are not protected against freezing by the safety/
drainage valve.
V
The drainage neck of the safety/drainage valve has to be free of dirt (e. g. leaves, ice)
at all times.
V
Further information on the living area battery can be obtained from chapter 8.
Содержание T-585
Страница 2: ...Instruction Manual T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN ...
Страница 10: ...1 10 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Introduction ...
Страница 36: ...4 36 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN During the Journey ...
Страница 74: ...6 74 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Living ...
Страница 82: ...7 82 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Gas Fittings ...
Страница 105: ...T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN 105 8 Electrical Fittings Fig 102 Circuit diagram interior E Box ...
Страница 106: ...8 106 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings Fig 103 Circuit diagram panel IT 991 ...
Страница 108: ...8 108 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Electrical Fittings ...
Страница 134: ...9 134 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Appliances ...
Страница 152: ...10 152 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Sanitary Fittings ...
Страница 160: ...11 160 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Care ...
Страница 172: ...12 172 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Maintenance ...
Страница 192: ...14 192 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Fault Search ...
Страница 214: ...16 214 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Technical Data ...
Страница 226: ...17 226 T Modell 04 05 Ausgabe 08 04 201804286 BUE 0006 04EN Helpful Notes ...