TROUBLESHOOTING GUIDE
The following guide was prepared to assist you in
solving simple problems with your spa. If the problem
with your spa cannot be solved after following these
procedures, please contact your authorized Bullfrog
Portable Spa Dealer.
PROBLEM:
Control Panel displays an error mes-
sage such as one of the following:
"
OHH
", "
OH5
",
"
ICE
", "
SnA
", "
Snb
", "
Sn5
", "
HFL
", "
LF
", "
drY
" or "
dr
".
Cause:
For causes and solutions, see “Diagnostic
Messages" under "OPERATION" in this Owner's Manual
for the Control System installed on your spa.
PROBLEM:
Control Pad and spa equipment do not
operate.
Cause: 1.
No electrical power to spa.
Solution:
A. Reset or turn on the GFCI circuit breaker.
B. Have a qualified electrician check your electrical
service.
Cause: 2.
The 30-Amp (20-Amp on Standard Control
System/BULF20) fuse in the Control System has blown.
Solution:
Contact your authorized Bullfrog Portable Spa
Dealer.
PROBLEM:
GFCI Breaker Repeatedly Trips.
Cause: 1.
Improper wiring to spa or GFCI breaker is de-
fective.
Solution:
Consult with electrician.
Cause: 2.
Defective component on spa.
Solution:
Contact your authorized Bullfrog Portable Spa
Dealer.
PROBLEM:
Spa pump turns off during operation.
Cause: 1.
Automatic timer has completed its 30 or 120
minute cycle.
Solution:
Turn on the pump at the Control Pad.
Cause: 2.
Pump has overheated due to vents in
equipment door being blocked.
Solution:
Clear items away from vents in equipment
door.
Cause: 3.
The pump motor is defective.
Solution:
Contact your authorized Bullfrog Portable Spa
Dealer.
PROBLEM:
Spa will not heat.
Cause: 1.
Slice Valve is partially or fully closed.
Solution:
Open Slice Valve and secure with Valve
Keeper.
Cause: 2.
Thermostat on Control Pad has been
turned down.
Solution:
Adjust thermostat to desired temperature
setting.
Cause: 3.
High Limit sensor has tripped.
Solution:
Touch any button on the Control Pad to
reset High Limit.
Cause: 4.
Heating System is defective.
Solution:
Contact your authorized Bullfrog Portable
Spa Dealer.
PROBLEM:
Spa Light does not work.
Cause: 1.
Light bulb has burned out.
Solution:
See "Light Bulb Replacement" in this
Owner's Manual.
Cause: 2.
Lighting System is defective.
Solution:
Contact your authorized Bullfrog Portable
Spa Dealer.
PROBLEM:
Spa pump will not turn on, creates
burning smell when running, or makes excessive
noise when running.
Cause:
Pump motor is defective.
Solution:
Contact your authorized Bullfrog Portable
Spa Dealer.
PROBLEM:
Jets surge on and off.
Cause:
Water level in spa is too low.
Solution:
Adjust water level to any point between the
two water level indentation marks on the back wall
of the filter/skimmer cavity.
PROBLEM:
Jets are weaker than normal or do
not work at all, but in both cases the pump is
running.
Cause: 1.
Jet handle(s) is partially or fully closed.
Solution:
Open jet handle(s).
Cause: 2.
Spa filter cartridge is dirty.
Solution:
See "Cleaning Your Filter" in this Owner's
Manual.
Cause: 3.
There is air trapped in the spa equipment
or its face piping.
Solution:
Open the air-bleed valve on each pump
housing and allow air to bleed out of system. Be sure
to tighten each air-bleed valve as soon as water
starts to flow out.
Cause: 4.
The Suction Fitting(s) are blocked.
Solution:
Remove any item or debris that is blocking