Page 14
Bullfrog Spas Owner’s Manual
Note:
Either pump can also be activated by an optional
auxiliary control button (if installed) (Fig. K1)
Light
Press the “Light” button to turn the light on and off. If
left on, the light automatically turns off after 4 hours.
Mode
Press “Temp Set”, then “Jets 2” (or “Aux”) to switch
between Standard, Economy, and Sleep Modes.
Standard Mode
is programmed to maintain the desired
temperature. Note: the last measured spa temperature
displayed is current only when pump 1 has been run-
ning for at least 2 minutes. “
St
” will be displayed
momentarily when you switch into standard mode.
Economy Mode
heats the spa to the set temperature
only during filter cycles. “
Ec
” will display solid when
temperature is not current, and will alternate with tem-
perature when temperature is current.
Sleep Mode
heats the spa to within 20°F of the set tem-
perature only during filter cycles. “
SL
” will display solid
when temperature is not current, and will alternate with
temperature when temperature is current.
Preset Filter Cycles
The first filter cycle begins 6 minutes after the spa is
energized. The second filter cycle begins 12 hours later.
Filter duration is programmable at the Master Control
Pad for 2, 4, or 6 hours. The default filter time is 4
hours. To program, press “Temp Set”, then “Jets1.”
Press “Temp Set” to adjust. Press “Jets 1” to exit
programming.
Pump 2 purges for 5 minutes at the beginning of each
filter cycle. The low speed of pump 1 runs during fil-
tration and the ozone sterilizer (if installed) will be en-
abled. If any button is pressed during filtering, the
ozone sterilizer (if installed) will be disabled for 60
minutes.
Temperature Display Inversion
Press the “Temp Set” button, then the “Jets 1” button to
invert display. Use the same sequence to revert back to
normal display.
Standby Mode
The spa can be disabled when the filter needs to be
serviced or when changing/servicing a JetPak™. Press
the “Temp Set” button, then the “Light” button, and the
display will show “
SY
.” All spa functions will be disabled
except for auxiliary freeze control. Press any panel
button to resume spa operation.
Freeze Protection
If the temperature sensors detect a drop to 40°F within
the heater, then pump 1 (and the heater if necessary)
will automatically activate to provide freeze protection.
The equipment stays on until the sensors detect that
the spa temperature has risen to within 15°F of the set
temperature. Pump 2 will purge for 1 to 2 minutes at
the end of the freeze condition.
(Figure K1) Auxiliary Control Pad
Wiring Diagram: Standard Control System