Page 20
Bullfrog Spas Owner’s Manual
Freeze Protection
If the temperature sensors detect a drop to 40°F within
the heater, then pump 1 (and the heater if necessary)
automatically activates to provide freeze protection.
The equipment stays on until the sensors detect that
the spa temperature has risen to within 15°F of the set
temperature. Pump 2 will purge for 30 seconds to 2
minutes at the end of the freeze condition. In colder
climates, an optional additional freeze sensor may be
added to protect against freeze conditions that may not
be sensed by the standard sensors. See your dealer for
details.
Locking the Panel
Press “Time” “Jets 1” then “Warm” within 3 seconds. All
buttons are frozen except the time button. The LCD
above the “Warm” button will light when the panel is
locked.
To unlock the panel, Press “Time”, “Jets 1” then “Cool.”
Locking the Temperature
Press “Warm” or “Cool” then “Time” and “Up” within 3
seconds to activate the lock. The LCD above the “Cool”
button will light when the temperature is locked.
To unlock the panel, press “Warm” or “Cool” then “Time”
and “Cool.”
DIAGNOSTIC MESSAGES:
No Message on Display:
Power has been cut off to the
spa.
Action Required:
The control panel will be disabled
until power returns. Spa settings will be preserved for
30 days with a battery back-up.
“
HTR TEMP LMT
”
on Display:
“Overheat” - The
spa has shut down. One of the sensors has
detected 118°F at the heater.
Action Required:
DO NOT ENTER THE WATER. Remove
the spa cover and allow water to cool. Once the heater
has cooled, reset by pushing any button. If spa does not
reset, shut off the power to the spa and call your
authorized Bullfrog Portable Spa Dealer.
“
SPA TEMP LMT
”
on Display:
“Overheat” - The
spa has shut down. One of the sensors has detected
that the spa water is 110°F.
Action Required:
DO NOT ENTER THE WATER. Remove
the spa cover and allow water to cool. At 107°F, the spa
should automatically reset. If spa does not reset, shut
off the power to the spa and call your authorized
Bullfrog Portable Spa Dealer.
“
FREEZE COND
”
on Display:
“Ice” - Auxiliary
Freeze Sensor detects potential freeze condition.
Action Required:
No action required. The pumps will
automatically activate regardless of spa status.
Содержание 2001 Portable Spas
Страница 41: ...Page 41 Bullfrog Spas Owner s Manual NOTES...