Bits Per second
This item sets the transmission speed for a serial port used in Console Redirection. Make sure
that the same speed is used in the host computer and the client computer. A lower transmission
speed may be required for long and busy lines. The options are 9600, 19200, 38400,
57600, and 115200 (bits per second)
.
Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits
and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select
Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the
parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want
to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity
bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent
with your data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data
communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
Flow Control
This feature allows the user to set the flow control for Console Redirection to prevent data
loss caused by buffer overflow. Send a "Stop" signal to stop send- ing data when the
receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer
is empty. The options are None and Hardware RTS/CTS
.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The
options are Enabled and Disabled
.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a
remote server. The options are Disabled and Enabled
.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and
Enabled
.
Legacy OS Redirection
Use this feature to select the number of rows and columns used in Console Redirection for
legacy OS support. The options are 80x24 and 80x25
.
Putty Keypad
Use this feature to select function key and keypad setting on Putty. The options are VT100,
LINUX, XTERMR6, SCO, ESCN, and VT400
.
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)
This item allows the user to configure Console Redirection settings to support Out-of-Band
Serial Port management
.
70
bullx R423-E3 - Installation and User's Guide
Содержание Bullx R423-E3
Страница 1: ...bullx R423 E3 Installation and User s Guide extreme computing REFERENCE 86 A1 48FH 01...
Страница 2: ......
Страница 24: ...14 bullx R423 E3 Installation and User s Guide...
Страница 28: ...18 bullx R423 E3 Installation and User s Guide...
Страница 43: ...5 7 1 Serverboard Quick Reference Chapter 5 Advanced Serverboard Setup 33...
Страница 44: ...34 bullx R423 E3 Installation and User s Guide...
Страница 62: ...52 bullx R423 E3 Installation and User s Guide...
Страница 92: ......
Страница 94: ...84 bullx R423 E3 Installation and User s Guide...
Страница 97: ......
Страница 98: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 48FH 01...