11

terminal shutdown event in Last 10 System Events. See
Fig. 29.

S

GEN (generator input) -- displays GENERATOR MAL-
FUNCTION pop--up message when G is energized. This
function requires the addition of a Generator Self Test

Verifier (Part No. GSV200) which must be purchased
separately. Visit

www.GeneratorVerifier.com

for details

and ordering information. See Fig. 28.

R

G

FE Fan Coil or 
Variable Speed Furnace

A07114

Fig. 28 -- G Input Wiring for Blower Operation or Generator

Malfunction with (--B) Evolution

t

Control

R

G

FE Fan Coil or 
Variable Speed Furnace

A07115

Fig. 29 -- G Input Wiring for System Shutdown

with (--B) Evolution

t

Control (Contact type selectable;

Normally Closed (default) or Normally Open)

High Stage Timer

Minimum amount of time low stage must operate before high stage
is activated. Ten to 60 minutes. 10 = default
A demand of 5

_

F / 2.8

_

C or more will override the staging timer.

Off Delay

S

90 seconds

S

120 seconds (default)

S

150 seconds

S

180 seconds

Amount of time the blower will continue to run after heating has
shut off.

Setup -- Fan Coil

HP/AC Airflow:

S

COMFORT (default) Cooling airflow is varied depend-

ing on humidity and temperature demand settings. This
selection enables the full dehumidify and comfort capa-

bilities of the system. When

COMFORT

is not selected,

the unit will not run reduced airflows for dehumidifica-
tion. Heat Pump airflow is varied depending on outdoor

temperature to maximize comfort.

S

EFFICIENCY -- fixed airflow used to achieve specified
ratings -- no dehumidification airflow reduction. This is

nominally 350 CFM/ton, but will vary if a 2--stage out-
door unit is used.

S

MAXIMUM -- 400 CFM/ton. Dehumidify features are

not active when set to maximum.

Dehum Airflow:

S

NORMAL (factory default) -- When equipment is run-
ning to dehumidify, the airflow is allowed to adjust to a
minimum to satisfy the dehumidification call.

S

HIGH -- Minimum airflow during the dehumidify mode
is increased to reduce duct and register sweating. Also

increases minimum airflow during normal cooling opera-
tion to reduce duct sweating.

Heater Size:

S

(choices dependent upon fan coil model)

This will show the heater size entered during the start--up process.

This value can be changed to another value (limited by the model
number of the fan coil). If the electric heater is self--identifying, this

value is not shown.

G Terminal

This setup option selects desired operation when the R--G circuit is
made on the fan coil control board.

S

DISABLED (Default)

S

FAN -- turns on fan to selected fan speed when G termi-

nal is energized. See Fig. 28.

S

FAN SPEED -- select Low, Med, High for all zones

when G terminal is energized.

S

SHUTDOWN -- shuts off fan and equipment when initi-

ated. This function may be activated by a dry contact
from an external device such as a float switch or a relay.
User selects whether the contact is NC -- normally closed

(default) or NO-- normally open. User Interface displays
SYSTEM MALFUNCTION on screen and registers G

terminal shutdown event in Last 10 System Events. See
Fig. 29.

S

GEN (generator input) -- displays GENERATOR MAL-

FUNCTION pop--up message when G is energized. This
function requires the addition of a Generator Self Test

Verifier (part No. GSV200) which must be purchased
separately. Visit

www.GeneratorVerifier.com

for details

and ordering information. See Fig. 28.

Setup -- Heat Pump / AC

Cooling Lockout:

S

NONE (default)

S

45

_

F / 7

_

C

S

50

_

F / 10

_

C

S

55

_

F / 13

_

C

Outside temperature below which cooling will not be provided.

Low Ambient Cooling:

S

NO (default)

S

YES

Selecting

YES

will enable the low ambient cooling operation in

the outdoor unit. This setting is only available with communicating

outdoor units and with Cooling Lockout set to

NONE

.

Entered Size:

S

(dependent on indoor unit model)

Size of the outdoor unit entered during the start--up process. If the

outdoor unit is a communicating model, this value will not be
shown. This size can be changed here but is limited to sizes that the

indoor unit can handle.

Defrost Interval:

S

30 minutes

BBU

IZ

01

--

B

Содержание EVOLUTION Zone Control SYSTXBBUIZ01-B

Страница 1: ...all local electrical codes during installation All wiring must conform to local and national electrical codes Improper wiring or installation may damage the Evolution Zone System Recognize safety info...

Страница 2: ...indoor unit outdoor unit and accessories accord ing to their instructions S Wire complete system according to this instruction S Setup commission and operate system according to this instruction to as...

Страница 3: ...the elements The Damper Control Module and zone dampers may be installed in any area where the temperature remains between 4_F to 158_F 20_C to 70_C and there is no condensation The cover must be inst...

Страница 4: ...essed Mount Interlocking Tabs 4 Recessed terminal block in wall 11 2 38 1 mm wide by 21 8 54 mm high A07150 Fig 7 Recessed Mount Assembly Surface Mount Backplate to wall Interlocking Tabs 4 A03191 Fig...

Страница 5: ...CAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation Improper wiring of the ABCD connector will cause the Evolution Zone System to operate improperl...

Страница 6: ...olation relay coil to furnace or fan coil HUM and COM terminals will allow the Evolution Zone Control to automatically energize the HUM output during a call for humidification The N O relay contacts w...

Страница 7: ...AC and the electric heater is not self identifying ELECTRIC HEATER NOT IDENTIFIED will appear See Fig 18 Press either Time or Temp buttons to select appropriate size of electric heater installed then...

Страница 8: ...Press right side button to start Duct Assessment Duct Assessment will measure the relative size of the ductwork up to and through the dampers These measurements are used to control the correct amount...

Страница 9: ...one schedule to other zones us ing NO or YES 11 Exit the scheduling mode by either closing the door or pressing the SCHEDULE button 12 If changes are made you will be asked to SAVE CHANGES YES NO INST...

Страница 10: ...ll settings in Install Service menus to factory default settings Last 10 System Events S Yes No to reset last 10 system events under Service Info menu Setup Furnace Upon a first time start up of the E...

Страница 11: ...midify mode is increased to reduce duct and register sweating Also increases minimum airflow during normal cooling opera tion to reduce duct sweating Heater Size S choices dependent upon fan coil mode...

Страница 12: ...er run time Airflow Limits Since bypass damper is prohibited in this system this setting is used to select the maximum allowable noise airflow relationship into each zone based on air noise and comfor...

Страница 13: ...e if the AC heat pump is a 2 stage model runs low speed only CHECKOUT MENUS CHECKOUT FURNACE HEAT PUMP HEATING HEAT PUMP COOLING HUMIDIFIER VENTILATOR BACK SELECT A03204 Fig 33 Checkout Menu The Check...

Страница 14: ...MEDIUM S HIGH default S MAXIMUM Because there is no bypass damper the Zone Airflow Limit check will allow the installer to assess the airflow noise generated by the system providing the maximum amoun...

Страница 15: ...er Control Module sensor will read leaving air temperature of the indoor unit The temperature information is for display purposes only The system does not react to this temperature reading Outdoor Coi...

Страница 16: ...is adjustable from 4 to 6 cycles per hour This timer is defeated for one cycle when the desired temperature is manually changed It can also be defeated for one cycle by simultaneously pressing the Fan...

Страница 17: ...a Equipment stage down or shut off if necessary b Fault history will record an event of AIRFLOW LIM ITED STAGEDOWN OCCURRED on stagedown and EXCESS STATIC PRESSURE if shut down c If shut down occurs o...

Страница 18: ...e a mistake on the start up screens and hit the right side button to get to the run mode How do I get back to start up 1 Press the ADVANCED button for at least 10 seconds 2 Install Service menu will a...

Страница 19: ...r Fault cooling mode only ventilator humidifier dehumidifier outdoor unit will be turned off Code 45 Control Circuitry Lockout NOTE For codes 13 14 and 21 the system will use heat pump heating exclusi...

Страница 20: ...nge at any time specifications or designs without notice and without incurring obligations E2007 Bryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in China Edition Date 03...

Отзывы: