Technical information
and start-up
Fast Charger
NLG6xx
51
7.4
Power limitations / Limiting controller
INFORMATION
To protect the charger and connected peripherals (e.g. HV battery, charging cable, Wallbox) from
damage due to overload, several load limits must be considered. The charger continuously monitors
whether all operating values are within the permissible range, and reduces charging power if
required (derating).
7.4.1
Input current limitation Indem
The input current is limited by the other limiters, the technical limits of the device, the charging cable
(Proximity Detection) and the charging station (Control Pilot).