7.3.2
WakeUp via Proximity
As soon as a charging cable is connected to the charging socket of the vehicle (Charge Coupler), the
charger detects the proximity resistor and wakes up. Also refer to chapter
3.4.7 Proximity Detection acc. to
7.3.3
WakeUp via Pin HW-WakeUp
The charger wakes up as soon as voltage at this pin exceeds 4.2 V (edge-controlled event). Now, the
charger tries to establish a connection via CAN to the higher-level control system (e.g. VCU).
7.3.4
WakeUp via Control Pilot CP
Control-Pilot (CP) is a standardized safety signal transmitted via an additional conductor in the charging
plug. The charging station can wake up the charger via CP signal. This function can be used e.g. to program
a specific charging period at the charging station in order to control the charge depending on electricity tariff.
7.3.5
WakeUp via AC (mains voltage)
The charger wakes up as soon as mains voltage is supplied to the contacts of the AC plug.