Technical information
and start-up
Fast Charger
NLG6xx
42
7.1.4.4
Pin 4 HVIL_out / Pin 9 HVIL_in
Internal
wiring
The (externally created and evaluated) interlock signal is transmitted over the DC plug. As a result, the
correct connection of the DC plug is constantly monitored. If the DC plug is disconnected or not
properly locked, the charger and battery should immediately be switched off by the external interlock
system, so dangerous situations can be avoided.
7.1.4.5
Pin 7 Kl31
This pin is directly connected to the housing (ground connection).
7.1.4.6
Pin 10 HW_WakeUp
Internal
wiring
Via this pin (HW_WakeUp), the charger can be woken up from sleep state.
7.3.3 WakeUp via Pin HW-WakeUp
10
0n
F
Pin 10
HW_WakeUp
1k
10n
F
1k
10k
1,0V
3,2V
22k
Pin 4
HVIL_OUT
Pin 9
HVIL_IN
47
0p
F
22
Ω
47
0p
F
49k
Ω
49k
Ω
DC-
Connector