PROBLEM
CAUSE
CORRECTIVE ACTION
12.
Pins jammed in overflow chute.
1
Dirty pins and/or dirt built up in pin
overflow chute.
1.
Clean pins with pin cleaner and/or
clean chute with all purpose
cleaner.
13.
Pin elevator turns continuously.
1.
Faulty Nexgen CPU or H.V. PCB .
1.
Replace Nexgen CPU or H.V.
PCB.
14.
Pinsetter runs for six seconds then
turns off.
1.
2.
3.
Elevator switch defective.
Pin jam in elevator.
Faulty Nexgen CPU PCB .
1.
2.
3.
Replace or adjust switch.
Remove pins.
Replace faulty electronic
assembly.
15.
Table motor runs continuously.
1.
2.
3.
Faulty switch A, or cam
misadjusted.
Missing screw on switch actuator.
Faulty Nexgen CPU or H.V. PCB .
1.
2.
3.
Adjust or replace actuator.
Replace screw or switch actuator.
cam as required.
Replace faulty electronic
assembly.
16.
Table sets pins but sweep stays
down.
1.
2.
3.
4.
5.
6.
7.
Sweep not fully forward.
Sweep attenuator stop screw not
adjusted properly.
Sweep pick up chain not adjusted
to proper length.
Sweep contacting gutter adapter
blocks.
Sweep release assembly bound.
Table motor running backwards.
Nexgen controller set table delay
set to "N"
1.
2.
3.
4.
5.
6.
7.
Move sweep manually by turning
middle pulley.
Adjust stop screw.
Adjust to proper length using
screw on end of chain.
Adjust sweep board.
Free bind in sweep release
assembly.
Re-wire motor for correct rotaion.
Set table delay to "Y".