GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
61
PROBLEM
CAUSE
CORRECTIVE ACTION
28.
Pinsetter operates erratically.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Faulty switch A.
Loose or faulty cables and
connections.
Switches B, C, or D, (on switch
cluster) or switch OOR (on setting
table guide tower) not adjusted
properly.
Setting table height not adjusted
properly.
Belts not tensioned properly.
Damaged pinsetter parts.
Pin holder latch not adjusted
properly.
Release levers damaged or not
adjusted properly.
Switch adjustment faulty or faulty
assembly.
Photocell adjustment not correct.
Faulty motor rotation.
Main power supply on too low a
voltage.
Faulty switch cluster cable, trouble
light, and ball door cable.
Faulty, ball lift cable, foul & optical
trigger cable.
After above checked, electronics.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Replace switch.
Use solenoid and cable checker.
Adjust switches or cam for B, C, or
D and OOR.
Adjust table height.
Check all belts for proper tension.
Replace or weld belts as required.
Repair or replace parts.
Adjust latch.
Replace levers or adjust as
required.
Check switch mountings.
Check adjustments.
Adjust ball detect.
Determine proper rotation and
adjust to proper phase status.
Use proper line voltage.
Substitute spare cable (to check).
Check cables and repair or
exchange.
Change the Nexgen CPU or H.V.
PCB