24
GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
Off Sweep Dwn: (Y, N, 45)
-
This option is available on machines with
firmware version 4.95.21 and higher.
The option causes the sweep to
drop when the lane is turned off from the scorer. The sweep will not drop
when the pinsetter is turned off via a local mechanic’s Stop/Run switch.
Y
- Enable sweep drop
N
- Disable sweep drop (default)
45
-
This option is available on machines with firmware version
4.97.11 and higher.
The option enables a delayed sweep drop. 45
seconds after the machine is turned off, the machine will cycle and
set 10 pins, but the sweep will stay down.
Auto Ball Ret: (Y or N) -
This option is available on machines with
firmware version 4.97.11 and higher.
This option determines how the
machine reacts to a ball detection when the machine is not in use.
Y -
When a ball detection occurs on a pinsetter that is not in use
(unassigned), the distributor, ball accelerator, and ball lift motors
will turn on. The distributor motor will run for 60 seconds to clear
pins out of the pit. The ball lift and ball accelerator motors will run
for 90 seconds to return the ball. The pinsetter’s table and sweep
motors remain off.
N -
Disabled (default)
Trouble Blink: (Y or N)
-
This option is available on machines with
firmware version 4.95.21 and higher.
The option determines whether
the light on the elevator will perform as a traditional trouble light and
be “off” during machine operation or as a status light and remain “On”
during machine operation.
Y
- Normally “Off”, “flashing” for errors.
N
- “Off” when machine is turned off, “On” when the machine is
operating, flashing for errors. (default)
ST Timing: (Y or N) -
The option is available on machines with
software version 4.97.02 and higher.
The option allows the mechanic to
choose which switch signal causes the spotting tong solenoid to de-
energize as the tongs return to their open position.
Y -
ST solenoid de-energize at the ST switch (default)
N -
ST solenoid de-energize at the B switch
NOTE:
Firmware versions prior to version 4.95.26 use the B switch timing.
Distrib Time: (45, 50, 55, 60)
-
This selection is available on machines
with firmware version 4.95.21 and higher.
Distributor time out. This
selection determines how long the distributor runs at the end of a
pinsetter cycle if an addition ball detection does not occur.
45
- 45 seconds (default)
50
- 50 seconds
55
- 55 seconds
60
- 60 seconds
Содержание GS-X Pinsetter