GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
47
Switch Status
Table
Sweep
Spotting
Tongs
Error
Code
“A” “G” “SM” “ST”
Problem
90
(Invld 0)
Actuated
Un-
Actuated
Un-
Actuated
Actuated
Sweep is up but it is not
forward.
91
(Invld 1)
Un-
Actuated
Un-
Actuated
Un-
Actuated
Actuated
Sweep is up but it is not
forward and the Table is
not at home position.
92
(Invld 2)
Un-
Actuated
Actuated
Un-
Actuated
Actuated
Sweep not forward, Table
is not at home position
93
(Invld 3)
Actuated
Un-
Actuated
Un-
Actuated
Un-
Actuated
Sweep is up but it is not
forward and the Spotting
Tongs are closed.
94
(Invld 4)
Un-
Actuated
Un-
Actuated
Un-
Actuated
Un-
Actuated
Sweep is up but it is not
forward, the Table is not
at home position and the
Spotting Tongs are closed.
95
(Invld 5)
Un-
Actuated
Actuated
Un-
Actuated
Un-
Actuated
Sweep is not forward, the
Table is not at home
position, and the Spotting
Tongs are closed.
Table 2. Invalid Machine States
NOTE
: Some errors or problems with the pinsetter may not be detected by the Pinsetter CPU.
Examples are ball accelerator problems or scoring errors.
Содержание GS-X Pinsetter
Страница 1: ...Operation Manual August 2019 47 902005 GBR GS X Pinsetter with Advanced CE Guarding...
Страница 14: ...14 GS X Pinsetter w Advanced CE Guarding Operation Manual GS Safety Mirror Safety Mirror...
Страница 62: ...62 GS X Pinsetter w Advanced CE Guarding Operation Manual Intentionally Blank...