GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
CODE EXTENDED
CODE *
FAILURE DESCRIPTION
POSSIBLE CAUSES
65
G Found
SWITCH G NOT EXPECTED BUT WAS
FOUND - This error is detected when
the sweep is down when it should be
up in the raised "waiting for a ball"
position.
1.
2.
3.
4.
Replacement table motor is wired so so the table is running backwards.
Sweep release assembly defective. Check for broken parts, missing spring or
a sticky solenoid plunger.
Sweep release assembly out of alignment causing it to miss the sweep during
the clockwise rotation of the table shaft.
Sweep wagon's forward position out of adjustment. Check both sweep arms
and make sure both sweep craNK links on the sweep shaft are tight.
"G" Switch shorted. Wiring between the Nexgen Controller and the switch is
shorted.
66
STFound
SWITCH ST NOT EXPECTED BUT WAS
FOUND - Spotting tong switch is actuated
when it should not have been. This
means that the tongs are in thier open position
when they should have closed.
1.
2.
3.
4.
5.
Spotting tong solenoid not energizing. Check fuses on Nexgen CPU PCB.
Spotting tong clutch slipping. Clean, reset tension and readjust.
One or more set of spotting tongs damaged or binding.
Drive gears on the square shaft or out of adjustment.
"ST" shorted or wiring on the table damaged.
67
OORFound SWITCH OOR NOT EXPECTED BUT
FOUND - The Out-of-Range switch,
located on the tower, is actuated when it
should not have been.
1.
2.
3.
The "OOR" switch is shorted or damaged.
The wiring from the switch to the Nexgen Controller is faulty.
The Nexgen Controller CPU may be defective.
70
A Ntfnd
SWITCH A EXPECTED BUT NOT FOUND -
Table is not at the fully raised to
"home" position.
1.
2.
3.
4.
"A" switch is defective or out of adjustment.
Table motor or brake defective.
Check wiring connections and motor and brake connections.
Reversing fuses on Nexgen High Voltage PCB that are blown.
71
BNtfnd
SWITCH B EXPECTED BUT NOT FOUND -
"B" switch was not made
when table lowered to detect or set
pins.
1.
2.
3.
4.
5.
Switch "B" defective or out of adjustment.
The wiring from the switch to the Nexgen Controller is faulty
The Nexgen Controller CPU PCB may be defective.
Reversing fuses on Nexgen High Voltage PCB that are blown
Table motor or brake is defective