PROBLEM
CAUSE
CORRECTIVE ACTION
17.
Full table lowers but does not
release all pins.
1.
2.
3.
Setting table not adjusted for
proper height.
Faulty pin holder solenoids or pin
holder microswitches.
Faulty electrical connections.
1.
2.
3.
Adjust setting table.
Repair or replace faulty solenoid or
microswitch.
Repair connections.
18.
Table does not set full rack of pins.
1.
2.
3.
4.
Faulty pin holder switches or switch
finger.
Pin detectors not allowed free
movement.
Faulty pin holder solenoid(s), or
cable harness's.
Faulty stroke limiter solenoid.
1.
2.
3.
4.
Replace switch or switch finger.
Determine cause and adjust as
required.
Replace solenoid(s). Check
harness cable and connectors.
Check stroke limiter solenoid and
wiring.
19.
Table makes long stroke only.
1.
2.
3.
Stroke limiter not adjusted properly.
Faulty solenoid.
Faulty cable.
1.
2.
3.
Adjust stroke limiter.
Replace or adjust solenoid as
required.
Repair or replace cable.
20.
Table makes short stroke only.
1.
2.
3.
4.
Faulty pin holder switch.
Faulty stroke limiter solenoid.
Pin holder shaft latch not adjusted
properly.
Faulty cable.
1.
2.
3.
4.
Replace switch or adjust .
Replace solenoid as required.
Adjust pin holder shaft latch.
Repair or replace cable.