MACHINE CLEANING
The frequency for cleaning the pinsetter depends on the type and quantity of lane conditioner (oil) used,
the environment that the pinsetter is operating, and the amount of bowling activity for the pinsetter.
In general the pinsetter should be kept as clean as possible using a vacuum, general purpose cleaner,
warm water (with detergent as needed), and 12:1 diluted lane cleaner such as Invincible.
CAUTION: Power to the pinsetter must be off when performing any machine
maintenance. Additionally the sweep board must be in the guarding position to
ensure that ensure a bowling ball cannot enter the pinsetter.
Cleaning the Transport Band
Suggested Work Location: Work Area 1
The following procedure should be used when cleaning the transport band.
1. Press the pinsetter reset button to lower the sweep board to its guarding position. Immediately
turn the stop/run on the mechanic’s remote display or the Nexgen box, to the stop position.
Turn off the main power switch on the Power Safety Controller box and lock the switch into the
off position using an approved lockout device.
2. Verify that all bowlers on the lane pair are off the approach and are not in a position to throw a
ball.
3. Lower the sweep board to prohibit a ball from entering the pinsetter.
4. Remove guards as needed to gain access to the transport band.
5. Wipe the top of the transport band using a solution of 12 parts water to 1 part lane cleaner (lane
cleaner diluted 12:1 with water).
6. Manually rotate the transport band to gain access to other side of the band.
7. Clean the remaining portion of the transport band.
8. Re-install all guards removed in step 4 and verify all interlock and sensors are in their proper
position.
9. Restart the Safety Controller:
If the Green “Restart Photocell” LED is “On” press the photo sensor restart button to
illuminate the yellow “Ready for Restart” LED, then press the restart button. If only the yellow
“Ready for Restart” LED is “On” press the restart button.
10. Once the machine has initialized, toggle the STOP/RUN switches for each machine off/on to
clear the power failure (PF) code.