STOPPING MACHINE IN MID-CYCLE
Suggested Work Location: Work Area 1
A machine may be stopped in mid-cycle by turning the stop/run switch on the Nexgen Controller
or mechanic’s remote display to the stop position. Once power is restored to the pinsetter it will
automatically return to home or ready to bowl position.
If internal service work is to be performed, turn off the main power switch on the Power Safety
Controller and lock the switch in the off position using an approved lockout device to prohibit the
machine from being turned on.
NOTE:
Removing the incoming 3 phase power will disable both pinsetters. Upon completion of
work, remove any installed lockout devices and turn the main power switch on. Restore power to
the Nexgen box by pressing the restart button on the Safety Controller.
Once the machine has initialized, clear the power failure (PF) error code by toggling both stop/
run switches off then on.