54
GS-X Pinsetter w/Advanced (CE) Guarding Operation Manual
PROBLEM
CAUSE
CORRECTIVE ACTION
3.
Pinsetter does not turn on properly.
1.
2.
3.
4.
5.
6.
7.
TS1 or TS2 safety switch actuated.
Photocell not adjusted properly.
Faulty switch "A" or "SM".
Nexgen Controller main switch is
off. The main power cable is
unplugged, the mechanic's rear
stop switch is not on.
Main house breaker box (if two
pinsetters are down.)
Incorrect line voltage.
Pinsetter set to wrong mode.
1.
2.
3.
4.
5.
6.
7.
Determine cause of trouble, repair,
and restart machine.
Adjust ball detector.
Replace or adjust switch.
Turn on all switches. Check plugs
and connectors.
Reset breakers.
Have line voltage corrected.
Set machine to proper mode
4.
Pinsetter cycles independently.
(One cycle only.)
CAUTION: Camera flash may
cause pinsetter to cycle
independantly.
1.
2.
3.
4.
5.
Photocell not adjusted properly.
Loose reflector mounting.
Faulty power supply connections.
Nexgen mode setting is wrong.
Incoming 3 phase power surge, or
is out of balance
1.
2.
3.
4.
5.
Check for proper hardware and
adjust.
Remount with proper hardware and
adjust.
Tighten connections.
Place pinsetter mode in 10-pin
mode (stand alone pinsetters) or in
(Frmwrx) mode if attached to the
Frameworx scorer.
As a last resort, consult a qualified
electrician to help identify the
surge and correct the problem.
Содержание GS-X Pinsetter
Страница 1: ...Operation Manual August 2019 47 902005 GBR GS X Pinsetter with Advanced CE Guarding...
Страница 14: ...14 GS X Pinsetter w Advanced CE Guarding Operation Manual GS Safety Mirror Safety Mirror...
Страница 62: ...62 GS X Pinsetter w Advanced CE Guarding Operation Manual Intentionally Blank...