CHAPTER 5 MAINTENANCE
5-25
8.
Move the Fusing Unit Pressure
Release Levers to the SET
position.
Fig. 5-23
9.
Install the Fuser Cleaner and the Oil Bottle into the new Fusing Unit and
lock the Oil Bottle Lock Levers and the Fuser Cleaner Lock Levers. Be
careful not to spill oil inside the printer. This could damage the printer.
Note
If the condition of the Fuser Cleaner is poor, we recommend that you replace
the Fuser Cleaner at the same time as the Fusing Unit. The life counter for
the Fuser Cleaner will need to be reset. Please refer to page
instructions.
Partially used Oil Bottles can be reused with a new Fusing Unit.
Please wait for 30 minutes after installing a new Fusing Unit to allow the
oil to circulate completely through the Heat Roller.
10.
Close the Top Cover, and then plug the printer into the AC outlet.
11.
Press the
Power
button to turn the printer On.
12.
Press any of the
Menu
buttons (
+
,
–
,
Set
or
Back
) to take the printer Off
Line.
13.
Press
+
or
–
until “RESET MENU” appears.
14.
Press
Set
to proceed to the next menu level, and then press
+
or
–
until
“PARTS LIFE” appears.
15.
Press
Set
, and then press
+
until “FUSER UNIT” appears.
Содержание HL-3450CN Series
Страница 46: ...CHAPTER 2 DRIVER AND SOFTWARE 2 12 Graphics Tab 1 Set the print quality ...
Страница 116: ...CHPTER 5 MAINTENANCE C C CH H HA A AP P PT T TE E ER R R 5 5 5 M M MA A AI I IN N NT T TE E EN N NA A AN N NC C CE E E ...
Страница 156: ...CHPTER 6 OPTIONS C C CH H HA A AP P PT T TE E ER R R 6 6 6 O O OP P PT T TI I IO O ON N NS S S ...
Страница 207: ...APPENDIX A A AP P PP P PE E EN N ND D DI I IX X X ...
Страница 220: ...APPENDIX A 13 I I IB B BM M M M M MO O OD D DE E E PC 8 PC 8 D N PC 850 PC 852 PC 860 PC 863 PC 865 PC 8 Turkish ...