Service Procedures
PreciseFlex™ DDR Collaborative Robots
P/N: PFD0-DI-00010, Rev 5.0.0, April 9, 2022
124
Copyright © 2022, Brooks Automation, Inc.
Gripper racks centered in fully open position
Replacing the Main Harness
Replacement of the Main Robot Harness is typically only performed at the factory. The Main Robot
Harness is intended to last for the life of the robot.
Replacing the J3 Clock Spring Harness to the J4 Motor
Tools Required:
1.
2.0mm hex driver
2.
2.5mm hex driver
Spare Parts Required: J3 Clock Spring Harness PN PFD0H-MA-00021
To replace the harness the user must:
1.
Remove the LED light tower and J3 Slave Controller per instructions for these
assemblies.