Software Reference
PreciseFlex™ DDR Collaborative Robots
P/N: PFD0-DI-00010, Rev 5.0.0, April 9, 2022
78
Copyright © 2022, Brooks Automation, Inc.
5.
If you wish to update the DDR motor cogging compensation tables, go back up to the top-level
directory and open the FLASH file, then open the sys file, then open the comp file. Paste the new
cogging compensation tables into the comp file, wait 15 seconds and then reboot the controller.
Updating GPL (System Software and Firmware)
GPL (the system software and firmware are now a single file in GPL 5.0 and later) may be upgraded in
the field. To perform an upgrade:
1.
Obtain the appropriate upgrade software from Precise, in the form of a .gz file.
2.
Use the Windows 10 File Explorer (NOT the Web Explorer) to access the ROMDISK GPL storage
area directly. Type "ftp://192.168.0.1/ROMDISK/bin" in the File Explorer address line.