Cryo-Torr 8600 Compressor Operation, Installation and Maintenance Guide
©2013 Brooks Automation Inc.
Pub. No. 8040564, Rev. AA, 01/15/13
ECO No. 64541
2-5
relays, refer to
and proceed as follows:
The setpoint relays are two mechanical relays that are incorporated into the
On-Board GLE Cryopump for the User's application. The relays are rated
at 1 amp at 25V AC/DC. The relays have both normally-open and
normally-closed contacts. Connection to the relays are made through the 9-
pin D connector labeled Relays on the connector plate on the On-Board
GLE Cryopump. Refer to
Refer to the appropriate
On-Board Module Programming and
Operation Instructions
for instructions on programming the setpoint
relays.
1. Determine whether your On-Board equipment requires setpoint
relay contacts to be either in a normally-open or normally-
closed position for your application.
2. Referring to
, prepare a 9-pin DSub mating connector,
meeting MIL DTL 24308/1-1 and equipment requirements.
3. Upon completion, connect the setpoint relay cable to the
RELAYS
connector on the On-Board Module.
4. Program the relays as described in the appropriate
On-Board
Module Programming and Operation
manual.
Figure 2-2: Setpoint Relays Connector Pin Identification
Normally Open (NO)
Normally Closed (NC)
Common
Common
Normally Closed (NC)
Normally Open (NO)
1
2
3
4
5
6
7
8
9
RELAY 2
RELAY 1
RELAYS
24V, 1 A
RS-232
REMOTE
AUX TC
NETWORK
Содержание On-Board 8
Страница 1: ...On Board GLE Cryopump Installation and Maintenance Instructions 8040564 Revision AA...
Страница 6: ...This Page Left Intentionally Blank...
Страница 8: ...This Page Left Intentionally Blank...
Страница 36: ...This Page Left Intentionally Blank...
Страница 52: ...This Page Left Intentionally Blank...
Страница 54: ...This Page Left Intentionally Blank...