NOTE
For information about the SFP+, mSFP, and QSFP transceivers that are qualified for the Brocade DCX
8510-8, go to http://www.brocade.com/downloads/documents/matrices/sfp-matrix-mx.pdf .
Providing power to the Brocade DCX 8510-8 Backbone
For this procedure, refer to
for power supply requirements for your chassis.
Complete the following steps to provide power to the chassis.
DANGER
Make sure that the power source circuits are properly grounded, then use the power cord
supplied with the device to connect it to the power source.
1. Connect the AC power cords to the power supply assemblies. Two or four power cords are required
depending on electrical service and if the high availability option is selected.
2. Connect the power cords to a power source with voltage of 200 to 240 VAC, 47 to 63 Hz (normally
two power cords or as many as four) or optionally to a power source with voltage of 110 to 120 VAC,
47 to 63 Hz (up to four power cords).
NOTE
Use of the high-voltage line (200 to 240 VAC) is highly recommended because of better power-
conversion efficiency. A DCX 8510-8 chassis fully loaded with 16 Gbps port blades (512 ports total)
should be supplied with four power supplies connected to 200-240 VAC lines.
3. Switch the AC power switches on the power supplies to I. The AC power switches light green when
switched on and power is supplied.
The Brocade DCX 8510-8 performs a power-on self-test (POST) each time it is powered on. POST
takes approximately 10 minutes and is complete when the indicator light activity displays the
operational state. You can bypass POST by using the
fastBoot
command. You can also disable
POST for successive reboots on the Brocade DCX 8510-8 using the
diagDisablePost
command.
NOTE
Do not connect the switch to the network until the IP addresses are configured.
For information about LED patterns, refer to
on page 49.
Port numbering
The Brocade DCX 8510-8 uses the following port numbering method (
page 137" ):
Providing power to the Brocade DCX 8510-8 Backbone
Brocade DCX 8510-8 Backbone Hardware Reference Manual
27
53-1002180-08
Содержание DCX 8510-8
Страница 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Страница 12: ...What s new in this document 12 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 148: ...Port Numbering Template 148 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 166: ...Brocade DCX 8510 Technical Specifications 166 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...