FRU
Description
Weight
Blower assembly
Two operating blower assemblies to ensure continuous
cooling of the system.
5.73 kg
12.60 lb
WWN bezel
Logo plate containing the two WWN cards beneath.
0.30 kg
0.60 lb
Cable management device Brocade DCX 8510-4: Two vertical cable management
finger assemblies.
Brocade DCX 8510-8: One cable management comb.
0.45 kg
1.00 lb
Chassis door
Chassis door for improved cable management.
2.09 kg
4.60 lb
Environmental requirements
Condition
Operational
Non-operational
Ambient temperature 0°C to 40°C (32°F to 104°F)
-25°C to 70°C (-13°F to 158°F)
Relative humidity
(non-condensing)
5% to 93% at 40°C (104°F) with maximum
gradient of 10% per hour
10% to 93% at 70°C (158°F)
Altitude (above sea
level)
0 to 3000 m (10,000 feet)
0 to 12000 m (40,000 feet)
Shock
20 G, 6 ms, half-sine wave
33 G, 11 ms, half-sine wave
Vibration
0.5 G sine, 0.4 gms random, 5-500 Hz
2.0 G sine, 1.1 gms random, 5-500 Hz
Airflow
Maximum: 90.1 cmh (53 cfm)
Nominal: 59.5 cmh (35 cfm)
N/A
Heat dissipation
Brocade DCX 8510-4: 4078 BTU/hr
Brocade DCX 8510-8: 7654 BTU/hr
N/A
Brocade DCX 8510 Technical Specifications
Brocade DCX 8510-8 Backbone Hardware Reference Manual
159
53-1002180-08
Содержание DCX 8510-8
Страница 1: ...53 1002180 08 19 September 2014 Brocade DCX 8510 8 Backbone Hardware Reference Manual ...
Страница 12: ...What s new in this document 12 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 22: ...Network manageability 22 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 34: ...Installing ICL cables 34 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 148: ...Port Numbering Template 148 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 166: ...Brocade DCX 8510 Technical Specifications 166 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...
Страница 172: ...Danger Notices 172 Brocade DCX 8510 8 Backbone Hardware Reference Manual 53 1002180 08 ...