NetXtreme II
User Guide
January 2010
Bro a d c o m C o rp o r a ti o n
Page 60
Appendix A: Event Log Messages
Document
ENGSRVT52-CDUM100-R
20
Error
Driver initialization failed.
Unspecified failure during
driver initialization.
Reinstall the driver, update to a
newer driver, run Broadcom
Advanced Control Suite 3
diagnostics, or replace the
adapter.
21
Informational
Network controller
configured for 10Gb full-
duplex link.
The adapter has been
manually configured for the
selected line speed and
duplex settings.
No action is required.
22
Error
Network controller failed
initialization because it
cannot allocate system
memory.
Insufficient system memory
prevented the initialization of
the driver.
Increase system memory.
23
Error
Network controller failed to
exchange the interface with
the bus driver.
The driver and the bus driver
are not compatible.
Update to the latest driver set,
ensuring the major and minor
versions for both NDIS and the
bus driver are the same.
Table 8: Base Driver Event Log Messages (Cont.)
Message
Number
Severity
Message
Cause
Corrective Action
Содержание BCM5706C
Страница 192: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 192 Configuring Teaming Document ENGSRVT52 CDUM100 R...
Страница 218: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 218 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 219: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 219...
Страница 220: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 220 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 221: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 221...
Страница 222: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 222 CE Notice Document ENGSRVT52 CDUM100 R...