Performing Diagnostics
Document
ENGSRVT52-CDUM100-R
P
ERFORMING
D
IAGNOSTICS
At the MS-DOS prompt, type
uxdiag
(for BCM5706/BCM5708/BCM5709 network adapters)
or uediag
(for BCM57710
network adapters) followed by the command options. The uxdiag command options are shown in
and the uediag
. For example, to run all diagnostic tests on adapter #1 except Group B tests:
C:\>uxdiag -c 1 -t b
NOTE: You must include
uxdiag
or
uediag
at the beginning of the command string each time you type a command.
Table 1: uxdiag Command Options
Command Options
Description
uxdiag
Performs all tests on all Broadcom NetXtreme II adapters in your system.
uxdiag -c <devnum>
Specifies the adapter (devnum) to test. Use
all
in place of a specific device number to test
all adapters.
uxdiag -cof
Allows tests to continue after detecting a failure.
uxdiag -F
Forces an upgrade of the image without checking the version.
uxdiag -fbc <bc_image>
Specifies the bin file to update the bootcode.
uxdiag -fib <ib_image>
Specifies the bin file for iSCSI boot.
uxdiag -fibc
Programs the iSCSI configuration block. Used only with -fib <ib_image>.
uxdiag -fibp
Programs the iSCSI configuration software. Used only with -fib <ib_image>.
uxdiag -fipmi <ipmi_image>
Specifies the bin file to update IPMI firmware.
uxdiag -fmba <mba_image>
Specifies the bin file to update the MBA.
uxdiag -fncsi <ncsi_image>
Specifies the bin file to update the NCSI firmware.
uxdiag -fnvm <raw_image>
Programs the raw image into NVM.
uxdiag -fump <ump_image>
Specifies the bin file to update UMP firmware.
uxdiag -help
Displays the Broadcom NetXtreme II User Diagnostics (uxdiag) command options.
uxdiag -I <iteration num>
Specifies the number of iterations to run on the selected tests.
uxdiag -idmatch
Enables matching of VID, DID, SVID, and SSID from the image file with device IDs. Used
only with -fnvm <raw_image>.
uxdiag -log <file>
Logs the test results to a specified log file.
uxdiag -mba <1/0>
Enables/disables Multiple Boot Agent (MBA) protocol.
1 = Enable
0 = Disable
uxdiag -mbap <n>
Sets the MBA boot protocol.
0 = PXE
1 = RPL
2 = BOOTP
3 = iSCSI_Boot
Содержание BCM5706C
Страница 192: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 192 Configuring Teaming Document ENGSRVT52 CDUM100 R...
Страница 218: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 218 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 219: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 219...
Страница 220: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 220 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 221: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 221...
Страница 222: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 222 CE Notice Document ENGSRVT52 CDUM100 R...