iSCSI Boot
Document
ENGSRVT52-CDUM100-R
NOTE:
When using a DHCP server, the DNS server entries are overwritten by the values provided by the DHCP
server. This occurs even if the locally provided values are valid and the DHCP server provides no DNS server
information. When the DHCP server provides no DNS server information, both the primary and secondary DNS
server values are set to 0.0.0.0. When the Windows OS takes over, the Microsoft iSCSI initiator retrieves the iSCSI
Initiator parameters and configures the appropriate registries statically. It will overwrite whatever is configured.
Since the DHCP daemon runs in the Windows environment as a user process, all TCP/IP parameters have to be
statically configured before the stack comes up in the iSCSI Boot environment.
If DHCP Option 17 is used, the target information is provided by the DHCP server, and the initiator iSCSI name is retrieved
from the value programmed from the Initiator Parameters screen. If no value was selected, then the controller defaults to the
name:
iqn.1995-05.com.broadcom.<11.22.33.44.55.66>.iscsiboot
where the string
11.22.33.44.55.66
corresponds to the controller’s MAC address.
If DHCP option 43 (IPv4 only) is used, then any settings on the Initiator Parameters, 1st Target Parameters, or 2nd Target
Parameters screens are ignored and do not need to be cleared.
To configure the iSCSI boot parameters using dynamic configuration
1.
From the
MBA Configuration Menu
, select
CTRL+K
.
2.
From the
Main
menu, select
General Parameters
.
3.
From the
General Parameters
screen, set the following:
•
TCP/IP parameters via DHCP
: Enabled. (For IPv4.)
•
IP Autoconfiguration
: Enabled. (For IPv6, non-offload.)
•
iSCSI parameters via DHCP
: Enabled
•
CHAP Authentication
: Disabled
•
Boot to iSCSI target
: Disabled
•
DHCP Vendor ID
: BRCM ISAN
•
Link Up Delay Time
: 0
•
Use TCP Timestamp
: Enabled
•
Target as First HDD
: Disabled
•
LUN Busy Retry Count
: 0
•
IP Version
: IPv6. (For IPv6, non-offload.)
•
Windows HBA Boot Mode
: Disabled
4.
Select
ESC
to return to the
Main
menu.
NOTE:
Information on the
Initiator Parameters
1st Target Parameters
, and
2nd Target Parameters
screens are
ignored and do not need to be cleared.
5.
A second iSCSI boot adapter can be configured for redundancy in the event the primary adapter fails to boot. To
configure the secondary device parameters, select
Secondary Device Parameters
from the
Main
menu (see
Parameters for a Secondary Adapter
). Otherwise, go to step 12.
6.
Select
Exit and Save Configurations
.
Содержание BCM5706C
Страница 192: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 192 Configuring Teaming Document ENGSRVT52 CDUM100 R...
Страница 218: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 218 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 219: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 219...
Страница 220: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 220 CE Notice Document ENGSRVT52 CDUM100 R...
Страница 221: ...User Guide NetXtreme II January 2010 Broadcom Corporation Document ENGSRVT52 CDUM100 R CE Notice Page 221...
Страница 222: ...NetXtreme II User Guide January 2010 Broadcom Corporation Page 222 CE Notice Document ENGSRVT52 CDUM100 R...