INSTALLER’S GUIDE
Page 4
1 A P P L I A N C E D A T A
This product uses a fuel effect piece containing Refractory Ceramic Fibres (RCF), which
are man-made vitreous silicate fibres. Excessive exposure to this material may cause
temporary irritation to eyes, skin and respiratory tract. Consequently, it makes sense to
take care when handling this article to ensure that the release of dust is kept to a minimum.
To ensure that the release of fibres from this RCF article is kept to a minimum, during
installation and servicing we recommend that you use a HEPA filtered vacuum to remove
any dust and soot accumulated in and around the fire before and after working on the fire.
When replacing this article we recommend that the replaced item is not broken up, but is
sealed within a heavy duty polythene bag, clearly labelled as RCF waste. This is not
classified as “hazardous waste” and may be disposed of at a tipping site licensed for the
disposal of industrial waste. Protective clothing is not required when handling this article,
but we recommend you follow the normal hygiene rules of not smoking, eating or drinking
in the work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or asbestos
related products.
The appliance data label is on the inner face of the back panel near the bottom left corner.
Gas
Natural (G20)
Inlet Pressure
20mbar
Gross Heat Input at Control Setting
4
5.05kW (17,200Btu/h)
3
3.45kW (11,800Btu/h)
2
1.80kW (6,100Btu/h)
1
1.55kW (5,300Btu/h)
Burner Test Pressure (Cold)
17.2±0.75mbar
(6.9±0.3in w.g.)
Gas Connection
8mm pipe
Burner Injector
Upper
Bray Cat. 99 Size 115
Lower
Bray Cat. 99 Size 230A
Pilot & Atmosphere Sensing Device
SIT Ref. OP9419
Ignition
Piezo-electric integral
with gas tap
Aeration
Non-adjustable