INSTALLER’S GUIDE
Page 23
Figure 16 Pilot air pipe location
7.8.4
Detach the gas tap bracket from
the right side of the appliance by
removing three screws. See figure 15.
7.8.5
Detach the left side of the burner
from the firebox by removing one
screw. See figure 15.
7.8.6
Free the burner & pilot module
from the rear pilot air pipe and the
firebox by carefully sliding the module
to the right while pulling it slightly.
See figures 15 and 16.
7.8.7
Remove the pipes, or pilot unit if
required.
7.8.8
Replace in the reverse order.
Note:1.
The pilot unit is an
atmosphere sensing device. It must be replaced as a whole assembly. Its
individual components are not separately replaceable.
2.
If the pilot is removed, when refitting, make sure that the pilot heat shield is
in place between the pilot unit and the rear of the burner and is the correct
way round. See figure 16.
3
.
Check that there is no blockage of the air intake tube at the back of the pilot
unit. Make sure that the air intake tube locates fully into the pilot air pipe
attached to the back panel. See figure 16.