INSTALLER’S GUIDE
Page 20
7 S E R V I C I N G & P A R T S R E P L A C E M E N T
•
Always turn off the gas supply before commencing any servicing (The appliance
inlet “T” connector incorporates an isolating valve).
•
It is recommended that, at least once a year, the appliance is disconnected and
the catchment space behind the closure plate checked and cleared of any debris.
The closure plate must be resealed to the wall after checking.
•
This product uses a fuel effect piece containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to this
material may cause temporary irritation to eyes, skin and respiratory tract.
Consequently, it makes sense to take care when handling this article to ensure
that the release of dust is kept to a minimum. To ensure that the release of fibres
from this RCF article is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust and soot
accumulated in and around the fire before and after working on the fire. When
replacing this article we recommend that the replaced item is not broken up, but
is sealed within a heavy duty polythene bag, clearly labelled as RCF waste. This
is not classified as “hazardous waste” and may be disposed of at a tipping site
licensed for the disposal of industrial waste. Protective clothing is not required
when handling these articles, but we recommend you follow the normal hygiene
rules of not smoking, eating or drinking in the work area and always wash your
hands before eating or drinking.
•
Check that soot or debris is not impairing the electrode spark or pilot burner.
•
Check that soot or debris is not blocking any of the holes in the main burner.
•
Always test for gas soundness and spillage after servicing the appliance.
7.1
To Remove Window Unit
7.1.1
Detach the window surround by sliding it upwards and then swinging the bottom
forwards (see figure 4 in the installation section). Lift and store carefully.
7.1.2
Remove the window unit by turning the screws each side of the window frame ¼
turn anticlockwise and lifting the unit clear (see figure 6 in the installation section).
7.1.3
Replace in the reverse order. Make sure that the coal is not dislodged when refitting.