Before continuing any further with the installation of this appliance please read the
following guide to manual handling

 

The lifting weight of this appliance is 16.86 kg. One person should be sufficient to lift
the fire. If for any reason this weight is considered too heavy then obtain assistance.

 

When lifting always keep your back straight. Bend your legs and not your back.

 

Avoid twisting at the waist. It is better to reposition your feet.

 

Avoid upper body/top heavy bending. Do not lean forward or sideways whilst
handling the fire.

 

Always grip with the palm of the hand. Do not use the tips of fingers for support.

 

Always keep the fire as close to the body as possible. This will minimise the
cantilever action.

 

Use gloves to provide additional grip.

 

Always use assistance if required.

Содержание Churchill LFE

Страница 1: ...his guide with the owner Manufactured exclusively for British Gas Scottish Gas by Valor Heating For Service Phone 0845 960 5040 Because our policy is one of constant development and improvement details may vary slightly from those given in this publication Valor Heating C h u r c h i l l L F E GC No 32 032 30 OUTSET RADIANT CONVECTOR LIVING FLAME EFFECT GAS FIRE Manufacturer ref 3413 ...

Страница 2: ...dow 16 5 FULL OPERATING CHECKS 16 5 1 Check Control Settings 16 5 2 Check Burner Pressure 16 5 3 Test For Spillage 17 5 4 Flame Supervision Spillage Monitoring System 18 6 FINAL ASSEMBLY REVIEW 18 6 1 Fit The Outer Case 18 6 2 Final Review 19 7 SERVICING PARTS REPLACEMENT 20 7 1 To Remove Window Unit 20 7 2 To Remove Outer Case 21 7 3 To Remove The Coal 21 7 4 To Remove The Gas Tap 21 7 5 To Remov...

Страница 3: ...oo heavy then obtain assistance When lifting always keep your back straight Bend your legs and not your back Avoid twisting at the waist It is better to reposition your feet Avoid upper body top heavy bending Do not lean forward or sideways whilst handling the fire Always grip with the palm of the hand Do not use the tips of fingers for support Always keep the fire as close to the body as possible...

Страница 4: ... clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling this article but we recommend you follow the normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drinking This appliance does ...

Страница 5: ...the current edition of the Building Regulations issued by the Department of the Environment and the Welsh Office In Scotland the current edition of the Building Standards Scotland Regulations issued by the Scottish Executive In Northern Ireland the current edition of the Building regulations Northern Ireland issued by the Department of the Environment for Northern Ireland In the republic of Irelan...

Страница 6: ...e steam is regularly present 2 7 The minimum allowable distance from the outside of the appliance case to a corner wall having combustible material or any other combustible surface which projects beyond the front of the appliance is 100mm at either side A clearance of 100mm should be maintained at the right side in all installations to allow satisfactory access to the control knob There is 10mm ac...

Страница 7: ...595191 When fitted this shall extend through the closure plate for at least 15mm and have a minimum clearance of 50mm from the end to any surface 2 9 1 Conventional Fireplace and Hearth The fireplace opening must be within the following dimensions Width Max 432mm Min 305mm Height Max 610mm Min 550mm Though the total height of the closure plate will accommodate a maximum opening height of 650mm hei...

Страница 8: ...e that has a precast concrete or clay flue block system conforming to BS1289 or BS EN 1806 The appliance is suitable for installations conforming to older versions of BS1289 as well as the current standards The flue blocks must have a minimum width not less than 63mm and a cross sectional area not less than 13 000mm2 Older editions of BS1289 required a cross sectional area of 13 000mm2 The current...

Страница 9: ... cause cracking of the surround back or marble 2 11 The following flues are suitable 225mm x 225mm conventional brick flue If a flue liner is used it must be a minimum of 125mm diameter The liner must be sealed to the surrounding area above the fireplace opening and to the top of the chimney An approved terminal must be fitted A properly constructed precast flue conforming to B S 1289 A flue pipe ...

Страница 10: ...2 13 The flue spigot and any spigot extension must be capable of passing through the closure plate by at least 25mm with a minimum clearance of 50mm between its open end and the nearest obstruction There must also be a minimum clearance of 165mm between the back of the closure plate and the back of the catchment space The catchment space below the flue spigot must extend at least 250mm downwards m...

Страница 11: ...be 1 Olive olive nut for gas line connection 1 Literature pack Remove all the items carefully to prevent damage Some items may be contained in the packaging fitments Examine the packaging carefully before discarding Check that all the items are present and undamaged 3 2 Fireplace Flue Pull Close all doors and windows in the room in which the appliance is to be installed After confirming with a mat...

Страница 12: ...ds to clear the fixing brackets Lift the case upward and forwards to clear the top location See figure 5 3 3 6 Two screws as shown in figure 4 secure the front fascia of the case These screws have been tightened to avoid damage to the case during transit These screws must be slackened to enable the customer to remove this section of the case Slacken the two screws detach the window surround by sli...

Страница 13: ...e spark gap is correct check the ignition wiring Remove the control knob after checking 3 3 10 For Wall Mounted Appliances Remove the levelling screws and locknuts from below the feet 3 3 11 If the fire is fitted to a recessed fireplace an extension flue spigot up to a maximum total length of 125mm may be used The extension must be a tight fit over the flue spigot and be secured by two self tappin...

Страница 14: ...sure that it overlaps the fireplace opening sufficiently to allow satisfactory sealing The bottom of the appliance must be at least 100mm above any carpet or other floor covering To achieve this the bottom of the flue spigot opening must be at least 565mm above the finished floor covering 3 4 3 Check the flue pull with closure plate fitted by applying a lighted match or smoke match to the flue spi...

Страница 15: ... these positions on the wall The positions can alternatively be marked by placing the fire in position and marking the wall through the holes in the back panel Drill and plug the holes using no 10 wall plugs Place the fire in position and secure with four no 10 x 2in woodscrews 4 3 Gas Supply Connection 8mm rigid tubing must be used to connect the gas supply to the appliance An olive and nut are p...

Страница 16: ...sed turn fully to the 1 IGN position A spark should be generated at the pilot while turning The spark should ignite the pilot 5 1 5 When pilot ignition has been achieved keep the control knob depressed for approximately ten seconds to allow the thermocouple probe to warm up and then release it If the pilot does not remain alight ensure that the air has been purged that the pilot orifice is clear a...

Страница 17: ...ck panel and with its top edge touching the side of the draught diverter box Slide the tube until the indent in the tube is level with the diverter side See figure 13 5 3 5 The installation is satisfactory if the smoke is drawn into the diverter box If an appreciable amount of smoke escapes from above the flue spigot or from the sides leave the appliance alight at the maximum setting for a further...

Страница 18: ...onitoring system must not be adjusted bypassed or put out of operation This monitoring system or any of its parts must only be exchanged using authorised parts 6 F I N A L A S S E M B L Y R E V I E W 6 1 Fit The Outer Case 6 1 1 Detach the control knob and control bezel 6 1 2 Refit the outer case The outer case top rear strip should locate in front of but touching the side extensions of the engine...

Страница 19: ... may give off a slight odour while new This is quite normal and it will disappear after a short period of use 6 2 7 Advise that any cleaning must only be carried out when the fire is off and cold 6 2 8 Advise the customer that they should read the Owner s guide before operating the fire and always follow the advice in the section headed Cleaning your fire 6 2 9 Advise the customer that the applian...

Страница 20: ... after working on the fire When replacing this article we recommend that the replaced item is not broken up but is sealed within a heavy duty polythene bag clearly labelled as RCF waste This is not classified as hazardous waste and may be disposed of at a tipping site licensed for the disposal of industrial waste Protective clothing is not required when handling these articles but we recommend you...

Страница 21: ...t the coal rests on the ledges at the sides of the firebox and that its back face is touching the horizontal rib at the back of the firebox See figure12 in the installation section 7 4 To Remove The Gas Tap 7 4 1 Remove the outer case as section 7 2 above 7 4 2 Detach the electrode lead from the pilot unit by pulling the lead down and away from the electrode situated at the centre rear of the burn...

Страница 22: ...lot in line with the mark previously made on the tap body 7 6 7 Reassemble the niting head and spindle complete with collar and spring making sure that the components are correctly engaged Check the operation of the tap 7 6 8 Refit the piezo generator 7 7 To Remove An Injector 7 7 1 Remove the outer case as section 7 2 7 7 2 Release the pipe compression fitting to the upper or lower injector as re...

Страница 23: ...15 and 16 7 8 7 Remove the pipes or pilot unit if required 7 8 8 Replace in the reverse order Note 1 The pilot unit is an atmosphere sensing device It must be replaced as a whole assembly Its individual components are not separately replaceable 2 If the pilot is removed when refitting make sure that the pilot heat shield is in place between the pilot unit and the rear of the burner and is the corr...

Страница 24: ...FF PART No A Upper Injector Bray Cat 99 Size 115 1 3001027 B Lower Injector Bray Cat 99 Size 230A 1 3001028 C Gas Tap Spark Generator 1 740K136 D Spark Generator 1 720A109 E Pilot Unit 1 3000970 F Inlet Isolating T Connector 1 020A050 G Window Unit 1 3000627 H Control Knob 1 630K378 J Coal 1 3001005 ...