INSTALLER’S GUIDE
Page 7
2.8
The minimum height required from the top surface of the appliance case to the
underside of any shelf made from wood or other combustible materials (see figure 1) is
shown in graph 1.
Important: No combustible material (e.g. Wallpaper, plastic tiling, wood panelling
etc.) must be used on the fireplace wall below the shelf.
2.9
In the United Kingdom, as supplied, this appliance can be installed in the following
situations:-
Note: A spigot extension is available (Part number 0595191). When fitted this shall extend
through the closure plate for at least 15mm and have a minimum clearance of 50mm from
the end to any surface.
2.9.1
Conventional Fireplace and Hearth
The fireplace opening must be within the following dimensions:
Width
Max.
432mm
Min.
305mm
Height
Max.
610mm
★
Min.
550mm
★
Though the total height of the closure plate will accommodate a maximum opening
height of 650mm, heights above 610mm will leave the closure plate and sealing tape
visible above the appliance.
The appliance must be mounted on a non-combustible hearth (N.B. conglomerate marble
hearths are considered as non-combustible). The hearth must be at least 710mm wide x
Graph 1 Combustible shelf clearances