INSTALLER’S GUIDE
Page 22
Figure 15 Burner Module Removal
7.6
To Grease The Control Tap
7.6.1
Detach the tap and remove the piezo
generator as section 7.5 making sure that
the tap is in the off position.
7.6.2
Remove the two screws from the
head of the tap. Remove the niting head
and spindle complete with collar and
spring.
7.6.3
Note the position of the slot in the
plug - mark its position on the tap body.
7.6.4
Remove the plug rotating slightly
while pulling.
7.6.5
Clean and grease the plug lightly
with suitable grease. Do not apply
excessive grease. Particularly, make sure
that the gas ports in the tap are not
restricted by grease.
7.6.6
Push the plug into the tap body and
position the slot in line with the mark
previously made on the tap body.
7.6.7
Reassemble the niting head and
spindle complete with collar and spring
making sure that the components are
correctly engaged. Check the operation of
the tap.
7.6.8
Refit the piezo generator.
7.7
To Remove An Injector
7.7.1
Remove the outer case as section 7.2.
7.7.2
Release the pipe compression fitting to the upper or lower injector as required. Lock
the injector with a second spanner to ensure that it does not move.
7.7.3
Loosen the pipe compression fitting at the tap end and move the pipe clear.
7.7.4
Remove the injector from the burner.
7.7.5
Replace in the reverse order.
7.8
To Remove The Complete Burner Module, Pipes and Pilot
7.8.1
Remove the outer case as section 7.2.
7.8.2
Remove the coal as section 7.3.
7.8.3
Support the inlet-isolating elbow to avoid straining the pipework and disconnect the
appliance from the elbow.