INSTALLER’S GUIDE
Page 6
2.5
Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by heat.
They may scorch or become discoloured when close to a heating appliance. Please bear
this in mind when installing.
2.6
The appliance must not be installed in any room, which contains a bath, or shower
or where steam is regularly present.
2.7
The minimum allowable distance from the outside of the appliance case to a corner
wall having combustible material or any other combustible surface which projects
beyond the front of the appliance is 100mm at either side.
A clearance of 100mm should be maintained at the right side in all installations to allow
satisfactory access to the control knob. There is 10mm access clearance from a non-
combustible surface necessary at the left side.
See figure 1.
Figure 1. Dimensions & clearances