INSTALLER’S GUIDE
Page 13
Figure 8 Closure Plate
Figure 7. Pilot Unit
3.3.9.
Check ignition spark
Before attempting to install, it is worth checking that the piezo electric spark ignition
system operates satisfactorily.
To initiate the spark, temporarily refit the control knob to
the tap spindle. Depress the control knob and while keeping
it depressed, turn anticlockwise through approximately 60°
to the 1/IGN position. A spark should track from the
electrode pin to pilot burner. If there is no spark or incorrect
tracking, check that the spark gap is between the limits
shown in figure 7. If the spark gap is correct, check the
ignition wiring.
Remove the control knob after checking.
3.3.10
For Wall Mounted Appliances
Remove the levelling screws and locknuts from below the
feet.
3.3.11
If the fire is fitted to
a recessed fireplace, an extension
flue spigot up to a maximum
total length of 125mm may be
used. The extension must be a
tight fit over the flue spigot and
be secured by two self tapping
screws. Note the minimum
clearance required as shown in
figure 2.
3.4
Fit The Closure Plate
See figure 8.
The closure plate has an opening
at the bottom for a central gas
feed pipe. The gap between the
pipe and this opening should be
sealed with tape after
connection. If a central feed pipe
is not required the opening
should be completely sealed with
tape.
3.4.1
Hearth mounting
See figure 9.