7
16
Fig. 33 – Typical Wet Charge Battery
The dry charged battery is manufactured with fully
charged plates. Electrolyte must be added at the time
that the battery is placed in service. Before activating a
dry charged battery, read and follow the manufacturer’s
recommended procedure.
Recommended battery sizes range from a minimum
30 ampere hour for warm temperature service to 50
ampere hour in coldest service.
WARNING: BATTERIES PRODUCE HY-
DROGEN, AN EXPLOSIVE GAS. Do not
store, charge or use a battery near an open
flame or devices which utilize a pilot light or
can create a spark.
Installation
1.
Before installing battery, connect all equipment to
be operated. Fig. 34.
2.
Place battery in holder with a flat base. Tighten
hold downs evenly until snug. DO NOT over
tighten.
3.
Connect positive terminal to positive post FIRST to
prevent sparks from accidental grounding. Tighten
connectors securely.
4.
Connect negative terminal to negative battery
terminal. Tighten connectors securely.
Fig. 34 – Typical 12 V Wiring Diagram
ALTERNATOR
SOLENOID
STOP
SWITCH
STARTER
MOTOR
+
-
12 VOLT
BATTERY
REGULATOR
RECTIFIER
HEAD
LIGHTS
6
KEY SWITCH
SOLENOID TAB
TERMINAL
BATTERY
TERMINAL
STARTER
TERMINAL
AC
OUTPUT
WIRES
HEAD
LIGHT
SWITCH
5
4
3
2
1
DC OUTPUT
WIRE
ANTI-AFTERFIRE
SOLENOID
Checking Battery
1.
Physical check – clean if necessary.
a.
Corrosion
b.
Dirt
c.
Terminal and clamps
(secure – good conditions)
2.
Bring battery to full charge.
DO NOT EXCEED CHARGE RATE OF 1/10 AMPERE
for every ampere of battery rating! CONSULT
BATTERY MANUFACTURER for charging REC-
OMMENDATIONS. Over charging may cause battery
failure.
a.
Use a taper charge (automatically reduces
charge rate).
b.
Fill battery cells with distilled water or tap
water (unless maintenance free type) after
charging (for batteries that have been in
service).
NOTE: If battery gets “hot” to the touch or is
spitting acid (gassing) excessively, unplug
charger periodically.
3.
With battery fully charged, check specific gravity
readings (unless maintenance free type) of each
cell with a Battery Hydrometer and record read-
ings (Fig. 35).
Fig. 35 – Checking 12 V Battery Cells
(Lead Acid, Wet Cell, With Fill Caps)
CHECK ALL
CELLS AFTER
CHARGING
USE TEMPERATURE
COMPENSATED
HYDROMETER
REPLACE IF
READINGS ARE
BELOW 1.225 OR IF
CELLS VARY BY MORE
THAN .50
All readings should be above 1.250 (compensating for
temperature). If specific gravity readings varied .50 or
if ALL cells read less than 1.225, replace battery.