4.6.3 DCC Power Supply
The DCC unit is equipped with a -48V DC / 50W power supply. The power plug is a
male 3-PIN D-sub(15) connector. A matching female plug is supplied with the DCC unit.
This plug should be soldered to the power cable in accordance with the drawing in
figure 5.
Figure 4: The DCC Power Plug
------------- A3 - Gnd
------------- A2 - Minus
--------------A1 - Plus
Figure 5: Soldering the Female 3-PIN D-sub(15) Connector to the Power Cable
4.6.4 Serial Number Location
The serial number of the ACC/DCC unit is located at the rear of the unit. The serial
numbers of the individual optional modules are located on the components side of the
modules. All serial numbers can also be found on the shipping box.
The serial number of the VB220 probe is also available via the web GUI under
About
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv