If the
Clear status
button is clicked the error counts are reset and the ETR 290
analysis restarts.
The details of the individual ETR 290 measurements are described in a separate
document called
Bridgetech ETR 290 Details - Extended ETSI TR 101 290
Testing
.
Clicking the
Show alarm graph
button opens the Alarm graph popup view.
The alarm graph shows the transport stream ETR alarm status over time in the form of
a status timeline. The timeline bar shows the stream status for a time span of 90
minutes, 8 hours or 24 hours as selected by clicking the time selection buttons below
the timelines. The stream bar reveals any alarm that has been present during the
selected time period. The bar colour is either green for OK or coloured in accordance
with the alarm severity if an alarm has occurred. Refer to section 6.2.2 for a
description of the alarm colour representation. Periods of time when the stream has
not been ETR monitored due to round-robin operation are represented by grey. By
using the arrow buttons it is possible to view alarm occurrences up to 24 hours back in
time even if the highest graph time resolution is selected.
If alarms have occurred during the selected time period, the status timeline will not be
all green. In this case it is possible to expand the timeline tree by clicking the plus sign
at the timeline. Individual timelines for different ETR priorities and for different alarms
may be viewed as the tree is expanded into several levels. Tooltips reveals details
about an error incident.
By default the 'Show only errors' mode is selected, and only timelines that are not all
green will be displayed. By clicking the
Show all checks
button it is possible to
access demodulator measurement graphs, if relevant. Note that graphs representing
MER, SNR and Signal strength are always present, irrespective of probe hardware
configuration. These graphs show the maximum and minimum values of the
parameter during the period.
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
120