ETR Thresholds - Priority 2:
Transport:
Enable or disable alarming of Transport error indicator errors
CRC:
Enable or disable alarming of checksum errors for tables
PCR:
Enable or disable alarming of Program Clock Reference errors
PCR - Maximum
interval (ms):
The maximum interval between reception of PCR values.
Default: 40 ms
PCR -
Discontinuity
threshold (ms):
The maximum change in the PCR value between two adjoining
PCR values (where the discontinuity indicator flag has not been
set).
Default: 100 ms
PCR Accuracy:
Enable or disable alarming of PCR Accuracy (PCR Jitter) errors
PCR Accuracy -
Jitter threshold
(ms):
The maximum allowed PCR jitter.
Default: 500 ms
PTS:
Enable or disable alarming of Presentation Time Stamp errors
PTS - Maximum
interval (ms):
The maximum allowed interval between the reception of two
PTS values.
Default: 700 ms
CAT:
Enable or disable alarming of Conditional Access Table errors
CAT - Maximum
interval (ms):
The maximum allowed section repetition interval for the CAT
table.
Default: 500 ms
Note that if both PCR checks are disabled in an ETR thresholds template the PCR for
the associated streams will not be processed and the
ETR 290 - PCR
view will not
display data for these streams.