The result of the different ETR 290 tests are shown as table entries in a condensed
view called MicroETR, a scaled down version of the regular ETR display, one icon
representing one stream. Green colour indicates status OK whereas red colour
indicates an active alarm for that particular test. A white field shows that a check has
not yet been performed, usually due to lack of measurement data, and grey indicates
that a check is disabled. Tool-tip functionality allows the user to view the name of an
individual check in the MicroETR display. Let the mouse pointer hover over the field for
a moment to view the tool-tip.
When clicking one of the MicroETR icons the detailed ETR 290 status for that stream is
displayed in the
ETR 290 - ETR Details
view. By entering this view through the
MicroETR, the view will remain static irrespective of the round-robin looping, thus
making it easy to examine one stream in detail without interruptions. The round-robin
looping and associated alarm handling will continue in the background.
Note that it is possible to deactivate individual ETR 290 alarms by defining appropriate
ETR thresholds
.
If the user wants to examine one particular Ethernet or demodulator stream in more
detail, he can lock the ETR 290 analysis to that stream by clicking the lock field at that
stream. The round-robin operation of the ETR 290 engine will then be stopped and a
lock icon will appear as an indication that the monitoring is locked to that stream. If a
time limit has been set for the time lock (
Setup - ETR
view), a clock icon will be
superimposed on the lock icon. To re-activate the round-robin cycling the lock icon
should be clicked. Note that locking the ETR 290 processing to one stream will affect
alarm handling and all ETR 290 views. Active alarms for streams that are not currently
being analysed will freeze (remain active) until the processing lock is deselected and
ETR 290 analysis eventually shows that the error state is cleared.
The user can select one input to be displayed exclusively by clicking the corresponding
Show only this input
button. This does not affect ETR 290 processing or alarming.
6.9.2 ETR 290 - ETR Details
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00
-
www.bridgetech.tv
118