RST:
Enable or disable alarming of Running Status Table errors.
Only relevant when DVB mode is selected.
TDT:
Enable or disable alarming of Time Date Table errors.
Only relevant when DVB mode is selected.
TDT - Maximum
interval (ms):
The maximum allowed section repetition interval for the TDT
and TOT tables.
Default: 30 000 ms
TDT - Require
TOT presence:
Check this checkbox if TOT presence is required.
Default: disabled
MGT:
Enable or disable alarming of Master Guide Table errors.
Only relevant when ATSC mode is selected.
MGT - Maximum
interval (ms):
The maximum allowed section repetition interval for the MGT
table.
Default: 150ms
VCT:
Enable or disable alarming of Virtual Channel Table errors.
Only relevant when ATSC mode is selected.
Require TVCT:
Require presence of the Terrestrial Virtual Channel Table.
Require CVCT:
Require presence of the Cable Virtual Channel Table.
VCT - Maximum
interval (ms):
The maximum allowed section repetition interval for the VCT
table.
Default: 400ms
PIM/PNM:
Enable or disable alarming of Program Information Message and
Program Name Message tables.
Only relevant when ATSC mode is selected.
Require PIM:
Require presence of the Program Information Message table.
Maximum
interval PIM
(ms):
The maximum allowed section repetition interval for the PIM
table.
Default: 500ms
Require PNM:
Require presence of the Program Name Message table.
Maximum
interval PNM
(ms):
The maximum allowed section repetition interval for the PNM
table.
Default: 1000ms
RRT:
Enable or disable alarming of Rating Region Table errors.
Only relevant when ATSC mode is selected.
RRT - Maximum
interval (ms):
The maximum allowed section repetition interval for the RRT
table.