NOTE
If the dispensing button or switching on of the cup
dispensing is not selected within 10 seconds of activating
the „UNLOCK“ button, the device will automatically block
the possibility of dispensing water.
Both of the above dispensing functions (automatic
dispensing and dispensing by means of a cup) will not work
when the device is not connected to the power supply.
•
Dispensing by means of a pump (power supply of
the device is not needed to dispense water in this
way)
a)
Place the cup under the water outlet (j) from the
device.
b)
Set the pump button (a) to the unlocked position (b).
c)
Press the pump (a) in order to dispense water into
the cup.
d)
After the end of dispensing, set the pump button (a)
to the locked position (b).
Setting the temperature of the „KEEP WARM“ mode
Press the temperature setting button (6) in order to change
the temperature at which the water will be maintained.
The standard setting is 85 ° C.
Each pressing of the button changes the temperature in the
following manner:
EN
•
Please ensure no access water near controls.
•
Do not turn the device upside down in order to dry
it. Leave the device in a vertical position for drying.
•
Do not wash the device in an automatic dishwasher.
•
Clean the outside surfaces of the device with a dry
soft cloth. Chemical agents are unnecessary.
•
The device must be descaled every 1-3 months.
•
Citric acid can be used as a descaler.
•
Do not scrub the inside of the device by means of
metal objects, nylon brushes, toothbrushes, etc.
because the material from which the device was
made may be damaged.
„CLEAN“ function – descaling
1.
Pressing the „CLEAN“ button will cause moving to
the cleaning mode and will boil water up to 100°C.
Cleaning will take 70 minutes.
2.
After 70 minutes, the display indication will stop
flashing.
Manner of using the „CLEAN“ function:
1)
Fill the water tank with water for full. Do not exceed
the maximum capacity.
2)
Add citric acid (about 15g or in a quantity depending
on the degree of water hardness)
3)
Close the lid and connect the device to the power
supply.
4) Press and hold the CLEAN button for about 3
seconds in order to activate the cleaning mode. In
the course of the cleaning process, other buttons will
be inactive.
5)
The water will be heated up to 100°C and kept at
high temperature for 70 minutes.
6)
In order to stop the cleaning mode, it is necessary to
press and hold the CLEAN button again for about 3
seconds.
NOTE! Do not leave the device unattended. Stay
close to the device in the course of cleaning.
7)
After completion of the cleaning process, the device
must be disconnected from and reconnected to the
power supply. In case the water has cooled down,
the device will boil it again. When the display lights
up green, the dispensing button will be active again.
8)
Pour the water out using the automatic dispensing
button.
When there is not enough water in order to pour
it out automatically it is necessary to wait until the
water and devices cool down, open the lid and pour
it out manually.
9)
Rinse the device tank with clean water and then refill
it. Install the lid and boil water.
10) Pour the water out using the automatic dispensing
button in order to make sure that no residual citric
acid has remained in the tank and pump.
11) Wipe the device with a soft cloth.
12) If the scale has remained in the device it is necessary
to repeat the cleaning process.
1
2
Reboil
Clean
TEMP
SET
Unlock
BOILING EMPTY KEEP
WARM
98°C 85°C 60°C 50°C 40°C
EN
Ensure good ventilation in the room in which the device
is used. The distance between each side of the device and
the wall or other objects should be at least 10 cm. Keep the
device away from hot surfaces. Operate the device on flat,
stable, clean, refractory and dry surfaces out of the reach
of children and people with mental disabilities. Install the
device making sure that constant access to the main plug is
ensured. The power cord connected to the appliance must
be properly grounded and correspond to the technical
details.
Before first use, remove all elements and clean them along
with the entire device
3.3. Device use
Opening the lid
1)
Press the front edge of the lever (l) that opens the lid
(c).
2)
Hold the raised end of the lever (l) that opens the lid
(c).
3)
Pull the lever (l) up. The lid (c) of the water tank will
open.
NOTE: The water inside and the steam coming out of the
device can be very hot and cause burns. Be careful and
keep a safe distance from the lid.
Removing the lid
4)
Open the lid (c) and set it at an angle of about 45°.
5)
Press the UNLOCK button located on the back of the
lid.
6)
Pull the lid (c) upwards at an angle of 45°.
Filling and topping up
7)
Open the lid (c) and fill the water tank with water
using a separate container for this purpose. When
pouring water, remember not to exceed the FULL
mark inside the device. Pouring greater quantity of
water may cause the water to spurt during boiling.
8) Close the lid and press it down until you hear
a clicking sound.
Boiling water and keeping warm
Turn on the device with the main switch (f). The water will
start boiling. When boiling water, it is prohibited to:
•
open the lid
•
pour more water
•
cover the steam outlet holes
A.
The red diode will light up in the course of heating
up water by the device.
B.
The LCD display shows the current water temperature.
C.
The set water temperature value during operation in
the „KEEP WARM“ mode.
The device will emit a „beep“ sound 5 times when the water
has been boiled.
The device will go to the mode of maintaining hot water,
the „KEEP WARM“ diode will light up.
D.
the „KEEP WARM“ diode lights up when the function
of keeping heat of water is on.
E. The LCD display shows the current water
temperature.
F.
The set water temperature value during operation in
the „KEEP WARM“ mode.
In case of pouring more water, press the RE-BOIL (8) button
so that the device will boil water.
„AUTO CUT-OFF“ mode – automatic switching off of
heating.
In case of lack of sufficient quantity of water in the device,
the power supply will be automatically disconnected.
Reasons for activating the „AUTO CUT-OFF“ mode:
•
Lack of water in the tank of the device.
•
Water level too low.
•
The lid is not properly closed.
•
Hot water is added after switching on the power
supply.
•
In the case of operation of the above mode, allow
the device to cool down, add water, disconnect from
the power supply and reconnect, then switch on the
device.
„RE-BOIL“ function of reboiling
a)
Press the „RE-BOIL“ button (8) once. The cooking
diode will light up.
b)
When the cooking process is completed, the device
will go to „KEEP WARM“ mode, the diode (3) will light
up.
•
„RE-BOIL“ mode will not start if there is no water in
the device.
•
Pressing the „RE-BOIL“ button (8) as soon as the
water boils will be ineffective because the water
temperature is already 100°C.
Dispensing water
NOTE: Do not press the water dispensing buttons when the
device tank is empty. It may lead to damage of the device.
•
Automatic water dispensing
1)
Press the „UNLOCK“ button (5) on the control panel.
The UNLOCK LED (4) will light up.
2) Place a cup under the water outlet (j) from the
device.
3) Press the automatic dispensing button (d) to
dispense water into the cup.
•
Activation of the dispensing by means of a cup
1)
Press the „UNLOCK“ button (5) on the control panel.
The UNLOCK indicator lamp (4) will light up.
2)
Put the cup under the water outlet (j) of the device.
3)
Using the cup, touch the water outlet of the device.
The device will start dispensing water.
A
B
C
BOILING EMPTY
KEEP
WARM
Temperature
98°C 85°C 60°C 50°C 40°C
D
E
F
BOILING
EMPTY
KEEP
WARM
Temperature
98°C 85°C 60°C 50°C 40°C
BOILING
EMPTY KEEP
WARM
98°C 85°C 60°C 50°C 40°C
•
In the course when the "KEEP WARM" mode is set
to the desired temperature, the "KEEP WARM" mode
diode will light up after the water has been boiled.
When the water temperature drops below the set
temperature, the device will heat the water and the
boiling diode will light during this time.
•
The temperature for maintaining the heat can be
set during the heat maintenance mode. The device
will automatically heat the water to the desired
temperature.
•
After each activation of the device it is necessary to
make sure that the temperature at which the water
will be kept corresponds to the user's requirements.
After each activation of the device, the temperature
of maintaining the heat returns to the initial setting:
85°C.
3.4. Cleaning and maintenance
•
Before each cleaning, adjustment, replacement
of accessories and if the device is not used, it is
necessary to pull out the mains plug and cool the
device completely.
•
Use cleaners without corrosive substances to clean
each surface
•
Use only mild detergents suitable for washing
surfaces which come into contact with food to wash
the device.
•
After cleaning the device, all parts should be dried
before reusing it.
•
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
•
Never spray the device with water jets.
•
Use a soft cloth for cleaning.
10
11
17.07.2018
98°C 85°C 60°C 50°C 40°C