background image

AUTODOME IP starlight 7000 HD

VG5-7230-CPT5 

 VG5-7230-EPC5 

 VG5-7230-EPR5

en

Operation Manual

Содержание VG5-7230-CPT5

Страница 1: ...AUTODOME IP starlight 7000 HD VG5 7230 CPT5 VG5 7230 EPC5 VG5 7230 EPR5 en Operation Manual ...

Страница 2: ......

Страница 3: ...r Supply Box 30 7 5 Make Connections in the Power Supply Box 32 7 6 Installing the VGA PEND WPLATE 33 7 7 Attach Pendant to Arm and Tighten 36 8 Installing the Roof Parapet and Pipe Mounts 38 8 1 Description 38 8 2 Route Wires and Attach Connectors 38 8 3 Attach Cover Door to Power Supply Box 44 8 4 Installing the VGA ROOF MOUNT 45 8 5 Installing the VG4 A 9543 Pipe Mount 47 8 6 Wire the Pipe Inte...

Страница 4: ...Display Stamping 87 17 5 GB T 28181 89 18 Web Interface 90 18 1 Appearance 90 18 2 LIVE Functions 91 19 Camera 92 19 1 Installer Menu 92 19 1 1 Positioning 92 19 2 Encoder Profile 92 19 3 Encoder Streams 95 19 4 Encoder Regions 96 19 5 Privacy Masks 97 19 6 Picture Settings 98 19 7 Lens Settings 101 19 8 PTZ Settings 102 19 9 Prepositions and Tours 104 19 10 Preposition mapping 104 19 11 Sectors 1...

Страница 5: ... 132 24 3 Certificates 132 24 4 Diagnostics 133 24 5 System Overview 133 25 Operation via the browser 135 25 1 Live page 135 25 1 1 Connection 135 25 1 2 PTZ 135 25 1 3 Prepositions 135 25 1 4 AUX Control 136 25 1 5 Intelligent Tracking 136 25 1 6 Digital I O 136 25 1 7 Special Functions 136 25 1 8 Special Functions 137 25 1 9 Special Functions 137 25 1 10 Recording status 138 25 1 11 Saving snaps...

Страница 6: ...AUTODOME IP starlight 7000 HD 2016 07 1 0 F 01U 283 679 Operation Manual Bosch Security Systems 26 2 Recommended Use of Your Camera 143 27 Troubleshooting 145 28 Maintenance 147 29 Technical data 148 30 User Command Table 149 ...

Страница 7: ...ardous situation which if not avoided could result in death or serious injury Caution Indicates a hazardous situation which if not avoided could result in minor or moderate injury Notice Indicates a situation which if not avoided could result in damage to the equipment or environment or data loss 1 4 Important Safety Instructions Read follow and retain for future reference all of the following saf...

Страница 8: ...able The unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect device for switching off the voltage for all units When High PoE or PoE 820 3at is used to power the unit the power is provided over the Ethernet cable which is then the main power disconnect device for switching off the voltage for all units 10 Power sources Operate the unit ...

Страница 9: ... combination to overturn Mount the unit per the installation instructions Camera lens An assembled camera lens in the outdoor housing must comply and be tested in accordance with UL IEC60950 Any output or signal lines from the camera must be SELV or Limited Power Source For safety reasons the environmental specification of the camera lens assembly must be within the environmental specification of ...

Страница 10: ...oduct may cause radio interference in which case the user may be required to take adequate measures FCC ICES Information U S A and Canadian Models Only This device complies with part 15 of the FCC Rules Operation is subject to the following conditions this device may not cause harmful interference and this device must accept any interference received including interference that may cause undesired...

Страница 11: ...ation de ce produit dans une zone résidentielle peut provoquer des interférences nuisibles Le cas échéant l utilisateur devra remédier à ces interférences à ses propres frais Au besoin l utilisateur consultera son revendeur ou un technicien qualifié en radio télévision qui procédera à une opération corrective La brochure suivante publiée par la Commission fédérale des communications FCC peut s avé...

Страница 12: ...in ceiling or indoor pendant applications that don t require heater power standard PoE 802 3at midspans or switches can be used to power the camera 1 7 Customer Support and Service If this unit needs service contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions Service Centers USA Telephone 800 366 2283 or 585 340 4162 Fax 800 366 1329 Emai...

Страница 13: ...c bubble and sunshield 1 Packet of printed Safety literature In Ceiling Quantity Item 1 AUTODOME IP starlight 7000 HD In Ceiling camera with tinted acrylic bubble and white trim ring 1 Interface box 1 Optional black trim ring 1 Ceiling gasket for IP54 conformance 1 Packet of printed Safety literature To mount an In ceiling mount model of AUTODOME 7000 you must purchase a Bracket Assembly Support K...

Страница 14: ...er with 120 VAC transformer or with 230 VAC transformer VG4 A PSU1 VG4 A PSU2 Pipe Mount with one of the following Power Supply Boxes VG4 A 9543 Power Supply Box and cover with 120 VAC transformer or with 230 VAC transformer VG4 A PSU1 VG4 A PSU2 The following table lists the optional parts sold separately that you may need for attaching a Pendant to the Roof Parapet and Pipe mount packages Mounti...

Страница 15: ...Roof parapet Mount Pipe Mount No 1 Socket 9 16 in Pendant Arm to Wall Mount Corner Mount Mast pole Mount Roof parapet Mount Pipe Mount No 1 Banding tool Bosch P N TC9311PM3T Mast pole mount Yes but sold separately from mount 1 Right angle NPS conduit connector 3 4 in 20 mm Mast pole mount with VGA PEND WPLATE No 1 Screwdriver medium straight blade Roof parapet Mount Pipe Mount No 1 Screwdriver No ...

Страница 16: ...16 en Unpacking AUTODOME IP starlight 7000 HD 2016 07 1 0 F 01U 283 679 Operation Manual Bosch Security Systems 1 Pliers In ceiling Mount No ...

Страница 17: ... products sold separately by Bosch or other manufacturers necessary to install AUTODOME cameras Quantity Product Part Number Size 1 SD card user supplied Water tight metal conduit user supplied 20 mm 0 75 in UL listed liquid tight strain reliefs user supplied Weatherproof sealant user supplied 4 Studs stainless steel corrosion resistant user supplied 6 4 mm 0 25 in to 8 mm 5 16 in ...

Страница 18: ... Intelligent Tracking Continuously follows an individual Intelligent Tracking operates by recognizing an individual in motion and zooms in to approximately 50 of the field of view for an average target height of six feet Snapshots Allows you to take and store individual video frames as JPEG images from the Web browser interface Record Allows configuration for the recording options of the IP module...

Страница 19: ...led outdoors All wiring power and I O cabling connecting to the unit must be routed separately inside different permanently earthed metal conduits not supplied Warning To minimize the potential for corrosion on the housing use only Bosch hardware and mounts See number 5 Installation in a corrosive environment in the section Recommended Use of Your Camera page 143 for more information 4 Install all...

Страница 20: ...r mast Use a pole designed specifically for CCTV cameras Do not use a tapered pole Do not use a pole that has signs or other equipment attached Consult EPA rating Wind load data to select an appropriate pole Roof Mounts Mount the camera in the most stable location on the roof Avoid locations affected by vibrations such as those caused by a rooftop air conditioner Use guy wires to stabilize the AUT...

Страница 21: ...e Warning Bosch recommends disconnecting power to the camera while adding or removing an SD card 1 Follow the steps in one of these sections depending on the type of camera mount Remove the bubble from an in ceiling housing page 65 or Remove the bubble from a pendant housing page 65 2 Locate the SD card slot item one in the figure below Figure 5 1 Camera cross section with SD card slot 3 Orient th...

Страница 22: ...commended The mounting material must be able to withstand this pull out force For example 19 mm 3 4 inch minimum for plywood 3 Place the Power Supply Box into the optional Trim Skirt 4 Secure the Power Supply Box to the mounting surface For a Wall installation Use four 4 corrosion resistant stainless steel studs not supplied Then proceed to Step 5 below For a Corner installation Secure the Corner ...

Страница 23: ...r Mounts en 23 Bosch Security Systems Operation Manual 2016 07 1 0 F 01U 283 679 Warning For units intended to be installed outdoors All wiring power and I O cabling connecting to the unit must be routed separately inside different permanently earthed metal conduits not supplied ...

Страница 24: ... A readily accessible 2 pole disconnect device with a contact separation of at least 3 mm 0 12 in must be incorporated Making the Connections Notice Refer to the Connection page 73 chapter for wire specifications and distances 1 Route all video control and alarm wires through the earth grounded conduit fitting on the right side of the power box 2 Route the high voltage 115 230 VAC lines through th...

Страница 25: ...ay Connector P104 Pin Description Pin Description Pin Description 1 Alarm Out 1 1 Alarm in 3 1 Alarm Out 4 Normally Open 2 Alarm Out 2 2 Alarm in 4 2 Alarm Out 4 COM 3 Alarm Out 3 3 Alarm in 5 3 Alarm Out 4 Normally Closed 4 Alarm Ground 4 Alarm in 6 4 Earth Ground 5 Alarm in 7 5 Analog Alarm 1 6 Alarm Ground 6 Analog Alarm 2 7 Ground For in ceiling mount only Low Voltage TTL 3 3V can also be used...

Страница 26: ...LINE NC NEUT Figure 7 4 Pendant arm power supply box 1 Ground Screw 7 P101 Connector Power In 120 VAC 220 VAC 2 From Harness Nexus cable bundle 8 P106 Connector Control In Out for external audio input and output 3 In Out 1 2 in 15 mm NPS Fitting 9 P105 Connector Audio to camera 4 Ethernet connector 10 Power In 3 4 in 20 mm NPS Fitting 5 P107 Connector 24 VAC to camera 11 Audio Input Output 3 4 in ...

Страница 27: ... No Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw P101 115 230 VAC or 24 VAC Power In Line NC Neutral P106 SERIAL COMMUNICATIONS CODE Audio IN Audio in signal ground CODE Audio IN Earth GND Ground Audio RXD Audio OUT TXD Audio OUT Audio out signal ground Signal GND Ground P107 24 VAC Power Arm Harness Camera 24 VAC Camera 24 VAC Earth Ground Heater 24 VAC Heater 24 VAC Table...

Страница 28: ... connected to the P101 connector and to the grounding screw The 24 VAC power out wire connected to the P107 heater power connectors GND TXD RXD C C GND TXD RXD C C P101 1 2 3 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2 1 6 5 4 3 2...

Страница 29: ...o obstruct closing the cover door 3 Attach the supplied 3 pin power plug to the incoming high voltage power wires in the box Refer to connector P101 in the table above and to the image below for an illustration of these connections P101 1 2 3 LINE NC NEUT Figure 7 6 Incoming 115 230 VAC power supply 4 Attach the ground wire to the grounding screw 5 Connect three wires to the P107 Power Out connect...

Страница 30: ... 6 5 4 3 2 1 6 5 4 5 4 3 2 1 6 5 4 5 4 5 4 6 5 4 5 4 6 5 4 5 4 5 4 6 5 4 6 5 4 6 5 4 3 2 1 3 2 1 6 5 4 3 2 5 4 3 2 3 2 5 4 3 2 P106 P105 P107 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 LED HTR DOME XD FUSE FUSE FUSE 24V NC 24V Figure 7 8 VG4 PA0 Power Supply Box 1 Incoming 24 VAC Power Supply Wires from VG4 PSU1 VG4 PSU2 power supply box 2 Ground Wire 3 P101 Connector 4 Control Data and ...

Страница 31: ...ng to the next step 3 While continuing to hold the top hinge pin open and align the top and bottom hinges of the Pendant Arm to their mating points on the Power Supply Box See the illustration above 4 Once you have aligned the hinges release the top hinge pin to engage its mating hinge on the power box Then release the bottom hinge pin from the Hinge Pin Stop to lock the Pendant Arm to the Power S...

Страница 32: ...m inputs and relay outputs connect the 4 pin Alarms Out the 6 pin Alarms In and the 7 pin Relay connectors from the Pendant Connector Harness to their mating connectors installed previously to the incoming alarm wires 6 Connect the 3 pin Power In Plug installed previously to its mating connector P101 on the left side of the box 7 Connect the incoming RJ45 video connector installed previously to it...

Страница 33: ...ncluded Secure the Mounting Plate to the Corner Plate using the four 4 3 8 x 1 3 4 inch bolts and split lock washers supplied 2 For a Mast or pole installation The metal straps included with the Mast mount accommodate a pole with a diameter of 100 380 mm 4 15 in You must use a banding tool sold separately for a mast or pole installation In addition you must obtain a 3 4 in 20 mm right angle condui...

Страница 34: ...pin lever up and holding it Note Both Hinge Pins must be fully compressed to open unlock the hinges of the Pendant Arm and before proceeding to the next step 3 While continuing to hold the top hinge pin open align the top and bottom hinges of the Pendant Arm to their mating points on the Mounting Plate 4 Once you have the hinges aligned release the top hinge pin to engage its mating hinge on the M...

Страница 35: ...nd distances 1 Route all incoming wires through one of the earth grounded conduits at the bottom of the Mounting Plate For a mast mount route all wires through the right angle conduit 2 Attach the water tight plug to the other conduit 3 Attach the grounding spade terminal item 1 below to one of the spade terminals inside the Mounting Plate Figure 7 13 Mounting Plate Inside Detail Ref Description 1...

Страница 36: ...able 7 13 Connect the incoming serial communication wires to the 6 pin mating connector supplied with the VGA PEND WPLATE kit Refer to the Power Supply Box Connections table above for details 14 Attach the 6 pin serial communication mating connector to the Serial Communications cable cable 8 15 Connect the Earth ground wire if available to the crimp ring terminal inside the Mounting Plate Note The...

Страница 37: ...me housing hook on the Pendant Arm hinge pin allowing the dome to rotate around the pin 3 Rotate the dome housing down to a vertical position and gently push upward to engage the connector on top of the dome housing Caution If you feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over 4 Hold the Pendant housing in position while tightening...

Страница 38: ...to maintain the integrity of a Type 4X environment the connected equipment must have a Type 4X environmental rating In order to maintain the integrity of a Type 4 environment the connected equipment must have a Type 4 Type 4X Type 6 or Type 6P environmental rating 8 2 Route Wires and Attach Connectors Power wires must be routed to the left front side of the Power Supply Box through a separate elec...

Страница 39: ...udio input and output in AUTODOME 7000 Series 2 P101 Connector 7 24 VAC Power Out 3 Ground Connection 8 P107 Connector 4 Transformer 9 Earth grounded conduit with power input and earth ground connection 5 Ethernet Wire 10 Earth grounded conduit with Ethernet video control audio input and output to head end system 11 Earth grounded conduit to camera Method Two is to bypass the Power Supply Box and ...

Страница 40: ...rface Board 1 120 VAC 230 VAC Power In 7 P101 Connector 2 P101 Connector 8 P107 Connector 3 Ground Connection 9 24 VAC Power In to camera 4 Transformer 10 Earth Ground 5 24 VAC Power Out 11 24 VAC Power In to camera 6 P107 Connector 12 24 VAC Power In to Heater 13 24 VAC Power In to Heater 14 Camera Power 15 Heater Power Wiring the Power Supply Box Notice Refer to the Connection page 73 chapter fo...

Страница 41: ...nnections section below Notice All video control and alarm wires either pass through the Power Supply Box or by pass it and connect directly to the Pipe Interface Board Wiring the Fiber Optic Model If installing a Fiber Optic model follow these steps Notice Refer to the Connection page 73 chapter for fiber optic specifications For instructions on installing a fiber optic module into a power supply...

Страница 42: ...Operation Manual Bosch Security Systems GND TXD RXD C C P101 P106 XF102 XF103 XF101 5 4 3 2 1 J103 J103 J103 J102 J101 LED HTR DOME 24V NC 24V FUSE FUSE FUSE FUSE Figure 8 17 Fiber Optic Ethernet Module installed 1 RJ45 Ethernet socket 2 Port for SFP module sold separately 3 Fiber Optic cable user supplied ...

Страница 43: ... J101 J101 J101 J101 J101 J101 J101 LED 6 5 4 3 2 1 GND GND GND TXD RXD C C XD XD XD XD HTR DOME FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE FUSE LINE NC NEUT Figure 8 18 Power Supply Box Connections 1 Ground Screw 5 Power In 2 Transformer 115 230 VAC Modes 6 In Out 1 2 in 15 mm NPS Fitting 3 In Out to camera 7 Power In 3 4 in 20 mm NPS Fitting 4 ...

Страница 44: ... while attaching the door GND TXD RXD C C GND TXD RXD C C FUSE FUSE FUSE 90 o HTR DOME LINE NC NEUT Figure 8 19 Align Cover Door Hinge to Power Box 1 Power Supply Box 5 Hold Hinge Pin Open 2 Cover Door 6 Open Position 3 Align Top Hinge 7 Hinge Pin Stop 4 Align Bottom Hinge 2 Open the top hinge by pushing its pin lever outward and holding it open Note Both Hinge Pins must be fully compressed to ope...

Страница 45: ...se the Parapet wall mount bracket as a template to mark the hole locations Notice Allow enough room below the Parapet Mount Bracket to route the video control and alarm wires up through the Parapet arm In certain installations you may have to lift the Parapet arm for the camera to clear the top of the wall when it is swung into position Provide enough slack in the wires to rotate the pipe arm over...

Страница 46: ...s steel fasteners three 3 on each side the bracket has eight 8 holes Be careful not to over tighten the fasteners because it may strip the threads If attaching the parapet mount to a flat roof attach the optional LTC 9230 01 Roof Mount Plate to the roof and then attach the Parapet Wall Bracket to the Roof Mount Plate 5 Insert the Parapet Pipe Arm into the mounting bracket until it bottoms in the b...

Страница 47: ...wn pipe and the Dome Cap 12 Proceed to Wire the Pipe Interface Board page 49 Notice Use a guy wire to aid in stabilizing the Parapet Arm Replace the 1 4 inch cap screw with a threaded 1 4 inch stainless steel eye bolt not supplied Loop the guy wire through the eye bolt and attach both ends to anchor spots on the roof 8 5 Installing the VG4 A 9543 Pipe Mount This section details the installation st...

Страница 48: ...9 mm 3 4 inch minimum for plywood 3 Attach pipe not supplied to the Top mounting Flange Warning You must thread the pipe onto the Top mounting Flange until it is tight Failure to do so can result in damage serious injury or death 4 Route the power video control and alarm wires through the Top Mounting Flange and down the pipe 5 Wrap at least five layers of Teflon tape around the threads 6 Apply th...

Страница 49: ...his section provides instructions for connecting wires and cables to the Pipe Interface Board as illustrated below Refer to the Connection page 73 chapter for cable and wiring recommendations and specifications BNC 7 5 6 4 3 2 1 2 1 2 1 3 J102 P107 P101 P102 P103 P104 P106 J101 AGND A7 A6 A5 A4 A3 AGND OUT 3 OUT 2 OUT 1 1 2 3 4 5 6 P105 Figure 8 25 Pipe Interface Board Connections ...

Страница 50: ... Note When using the audio input in an AUTODOME 7000 Series camera remove this resistor P105 6 Data In Out P105 AWG 26 16 1 Biphase C For AUTODOME 7000 Series AUDIO IN Audio in signal ground 2 Biphase C For AUTODOME 7000 Series AUDIO IN 3 Earth Ground 4 RxD For AUTODOME 7000 Series AUDIO OUT 5 TxD For AUTODOME 7000 Series AUDIO OUT Audio out signal ground 6 Signal Ground 7 Alarms In EOLR Supervise...

Страница 51: ... on the Pipe Interface Board 2 Attach the control data in out wires to their respective terminals on the P105 connector on the Pipe Interface Board 3 Connect the 24 VAC power wires to the P101 connector on the Pipe Interface Board If this model has a heater connect the 24 VAC heater power wires to connector P107 Caution To protect the camera from damage due to cold temperatures ensure that you con...

Страница 52: ...ound 5 Alarm in 7 5 Analog Alarm 1 6 Alarm Ground 6 Analog Alarm 2 7 Ground For in ceiling mount only Low Voltage TTL 3 3V can also be used 4 Connect the plugs to their mating connectors P103 and P102 on the Pipe Interface Board 1 To connect supervised alarms and relays attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board see above 2 Insert the Pipe Int...

Страница 53: ...1 Tilt Dome 2 Hook and drop 2a Dome Cap 2b Recessed Hinge Pin 2c Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mounting screws to a minimum torque of 10 12 N m 90 105 in lbs 3 Drop the Pendant down slightly to engage the dome hook and hinge pin of the Dome Cap allowing the dome to rotate around the hinge pin 4 Rotate the dome housing down to a vertical position and gent...

Страница 54: ...lling a Parapet Roof Mount 7 Tighten the three 3 10 mm 3 8 inch stainless steel hex bolts on the bracket to lock the Parapet Arm in position Caution Do not over tighten the bolts The maximum torque is 34 N m 25 ft lb 8 8 Make Connections in the Power Supply Box 1 Attach the earth ground wire to the grounding screw on the left side of the box 2 Connect the 24 VAC to Dome plug installed previously t...

Страница 55: ...wall Ceiling for Installation 1 Choose the desired location to mount the camera 2 Use the bracket Base Plate as a template to cut a 7 in hole with a tolerance of 1 8 in 177 8 mm 2 2 mm in the ceiling with a drywall utility saw or Jig Saw Proceed to Wire the Interface Box page 57 for further instructions 9 4 Prepare Suspension Ceiling for Installation You must use the VGA IC SP In ceiling Support K...

Страница 56: ...3 Securing Screw 4 2 Base Plate 4 Bar Clips 1 Use the bracket Base Plate as a template or cut a hole sized hole in the center of the ceiling tile with a drywall utility saw or jig saw Figure 9 31 Cut Hole in Ceiling Tile 2 Tighten the four 4 securing screws to the Bracket Assembly Figure 9 32 Tighten Bracket Securing Screw 3 Secure the Bracket Assembly to an overhead securing point with a safety w...

Страница 57: ...he top or side Use the supplied rubber plug to seal the hole which will not be used to route wires Figure 9 34 Interface Box Connections After routing all video control power and alarm wires 1 Attach a 3 4 inch NPS 20 mm conduit fitting to the hole in which you bring in the wires Be sure to thread the inside nut to the conduit fitting 2 Route the video control power and alarm wires through the con...

Страница 58: ...lying lead wires to the appropriate incoming alarm wires Alarm Out 4 is a relay 1 1 2 3 4 5 6 2 3 4 N O COM N C A1 GND A2 1 PIN PIN P102 P103 P104 WHITE ORANGE BROWN GREEN WHITE ORANGE BROWN GREEN YELLOW BLUE 2 3 4 5 6 7 Figure 9 35 Alarm and relay connectors 1 4 pin Alarm Connector P102 2 6 pin Alarm In Connector P103 3 7 pin Relay Connector P104 Pin Description Pin Description Pin Description 1 ...

Страница 59: ... 6 Interface Box Connections The following figure is a detailed illustration of the In ceiling Interface box P105 P104 P102 P103 J101 J102 24VAC 24VAC P101 SIG GND TXD RXD C C NC NO COM AGND A2 A1 J103 A3 A4 A5 A6 A7 AGND AGND OUT3 OUT2 OUT1 Figure 9 36 In ceiling Interface Box 1 Fiber Optics 5 Coax Video Not applicable for AUTODOME 7000 Series cameras 2 Ethernet Video 6 Alarm In 3 Dome Power 7 An...

Страница 60: ...d output for AUTODOME 7000 Series cameras however their labels are still those of previous versions of analog AUTODOME cameras Warning 24 VAC Class 2 power supply only 9 7 Installing the Ceiling IP54 Housing Gasket In order to conform to the IP54 rating you must install the ceiling gasket illustrated along with the other pieces that protect the camera and provide the IP54 rating in the figure belo...

Страница 61: ... 2 Black Trim Ring supplied in the shipping box of the camera 6 Ceiling IP54 housing Gasket 3 Bubble 7 In ceiling housing 4 Trim Ring Gasket 1 Place the gasket provided in the shipping box of the camera over the top of the in ceiling housing 2 Carefully slide the gasket down over the housing until it rests on the flange of the housing 9 8 Attach Housing to the Interface Box The In Ceiling Housing ...

Страница 62: ...e ball studs of the In Ceiling Housing to the Stud Retainers on Interface Box and attach 3 Tighten the two 2 Thumbscrews to secure the Interface Box to the housing Figure 9 39 In Ceiling Housing and Interface Box 1 Interface Box 4 Thumb Screw 2 Ball Stud 5 Tether Point 3 In ceiling Housing 6 Ceiling Clamp Caution The In ceiling dome is provided with tether points on each side of the housing To pre...

Страница 63: ...o the ceiling by two 2 screw clamps 1 Insert the In ceiling Mount Assembly through the hole in the ceiling 2 Tighten both clamps using a 2 Phillips screwdriver to secure the housing to the ceiling mm inches 40 mm 1 57 in MAXIMUM CEILING 6 5 mm 0 26 in MINIMUM CEILING Figure 9 40 Secure camera to ceiling 1 Tether Point 4 Ceiling Clamp 2 Ceiling Clamp 5 Rotate Clockwise to Engage Clamp 3 Tether Poin...

Страница 64: ...U 283 679 Operation Manual Bosch Security Systems Caution Over torquing the Ceiling Clamps can damage the clamp or ceiling Only tighten the clamp until it contacts the ceiling and you start to feel some resistance If using a power screwdriver set the torque level to the lowest setting ...

Страница 65: ...es Remove the bubble from an in ceiling housing 1 Loosen the lockscrew item 1 in the illustration below in the trim ring using a P1 or smaller Phillips screwdriver until the bubble can rotate freely 2 Then rotate the bubble counterclockwise approximately 1 4 turn until it releases from the In Ceiling Housing See the figure below for an illustration Figure 10 41 Bubble Release Screw 3 Remove the fo...

Страница 66: ...omes assembled with a white trim ring An optional black trim ring is supplied in the shipping box To replace the white trim ring follow these steps 1 Remove the four 4 Phillips head screws from the inner ring 2 Remove the white trim ring 3 For In ceiling models verify that the trim ring gasket is in place Refer to the graphic in Installing the Ceiling IP54 Housing Gasket page 60 for an illustratio...

Страница 67: ...ures that you align both screw slots Warning Trim ring can become deformed If the trim ring is not turned completely the screw slot on the trim ring will not be aligned with the screw slot in the housing You cannot see the screw slot in the housing when you are turning the screw in the slot in the trim ring You can turn the screw in the slot in the trim ring but miss the screw slot on the housing ...

Страница 68: ...trim ring using a P1 or smaller Phillips screwdriver until the bubble can rotate freely 2 Rotate the bubble counterclockwise approximately 1 4 turn until it releases from the in ceiling housing Notice For VGA BUBBLE CCLR and VGA BUBBLE CTIR you must reuse the rings that came with the bubble that you are replacing Continue with steps 3 through 8 3 Turn over the bubble and trim ring assembly so that...

Страница 69: ...with the slots on the outer trim ring 7 Place the inner trim ring over the bubble and align the lock screw slot on the inner ring with the lock screw slot on the outer trim ring item 3 above 8 Secure the inner ring to the outer ring using the four screws removed earlier 9 Clean the bubble according to the instructions in the section Maintenance 10 Place the replacement bubble and trim ring assembl...

Страница 70: ...ow steps 3 6 Otherwise skip from step 2 to step 7 Notice The following four 4 steps are for replacing the trim ring These steps are optional If you are not replacing the trim ring skip to step 7 1 Remove the five 5 Phillips head screws from the inner ring 2 Remove the white trim ring 3 Place the black trim ring over the inner ring 4 Replace and tighten the five 5 screws 5 Clean the bubble accordin...

Страница 71: ... in the section Maintenance 3 Place the replacement bubble onto the in ceiling housing and rotate it clockwise approximately 1 4 turn until it stops Then tighten the lock screw Notice Trim ring can become deformed If the trim ring is not turned completely the screw slot on the trim ring will not be aligned with the screw slot in the housing You cannot see the screw slot in the housing when you are...

Страница 72: ...e the bubble counterclockwise approximately 20 degrees until the bubble assembly releases from the pendant housing 4 Locate the four tabs item 1 below inside the trim ring that attach the trim ring to the bubble 5 Gently push each tab out and down away from the bubble to disengage the tabs 6 Remove the bubble from the trim ring 7 Insert the replacement bubble inside the trim ring and align the rel...

Страница 73: ...ow 1 2 3 4 1 2 2 4 Figure 15 45 AUTODOME 7000 Series System Configuration 1 AUTODOME 7000 Series 2 IP Connection 3 Network Switch 4 Computer Notice You can also use the Bosch Video Client software application to configure the network settings for an AUTODOME 7000 Series camera Go to www boschsecurity com to download the Configuration Manager software and Operating Manual 15 2 Power Cable and Wire ...

Страница 74: ...compliant with the IEEE 802 3at class 4 standard The camera can be connected simultaneously to a 24 VAC power supply and to a High PoE 60 W midspan The camera uses power from the 24 VAC power supply If this power supply fails the camera seamlessly switches power input to the High PoE 60 W midspan The camera switches back to the 24 VAC power supply once power is restored Refer to Using the IP Inter...

Страница 75: ...undling requirements and limitations 15 4 Fiber Optic Ethernet Media Converter Optional The fiber optic media converter is designed to transmit 10 100 Mbps Ethernet signals over fiber optic cable using 10 100 Mbps Small Form factor Pluggable SFP modules The SFP modules are available as multi mode fiber MMF or single mode fiber SMF models with a single SC connector or dual fiber with an LC connecto...

Страница 76: ... on how the alarm is configured a short or a break in the alarm s circuit can trigger the tamper signal Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through Configuration to either Normally Open N O or Normally Closed N C Notice Only Alarms 1 and 2 pins 5 or...

Страница 77: ...me Connector 2 Alarm 1 or 2 only Pin 5 or 6 4 Ground Pin 7 3 From Configuration select Interfaces Alarm Inputs select the number of the Alarm input and finally select N C See the table below for contact and condition details AUTODOME Programmed N C S Contact Alarm Condition Open Alarm Closed Normal Short Tamper Configuring Non supervised Alarms inputs 3 through 7 You can configure alarms 3 through...

Страница 78: ...C See the table below for contact and condition details AUTODOME Programmed N C Circuit Alarm Indication Open Alarm Closed Normal Alarm Outputs The camera incorporates two 2 types of alarm outputs one dry contact relay and three 3 open collector outputs or transistor outputs Configuring a Dry Contact Relay The dry contact relay acts like an on off switch It has a maximum voltage rating of 2 A 30 D...

Страница 79: ...s should be complied with in all cases Max Input Voltage 1 Vrms Impedance 9 K Ω typical Shield Bare copper braid 95 coverage Internal gain level adjustment is available in case the signal level is too low Audio Line Output Specifications The following Line Output specifications should be complied with in all cases Typical Output Voltage 1 Vrms Impedance 1 5 K Ω typical Shield Bare copper braid 95 ...

Страница 80: ... to the Audio_Out RXD output terminal 2 Connect the audio line level output signal ground to the Audio_Out TXD output terminal Figure 15 50 Connections for audio over an Ethernet network 1 Audio_In C 7 AUTODOME Data In Out 2 Audio_In C 8 P105 P106 Connector 3 Earth Ground 9 Audio Out 4 Audio_Out RXD 5 Audio_Out TXD 6 Signal Ground Notice Separate the audio cables from the AC power lines to avoid n...

Страница 81: ...d mode on the Security tab under Internet Options You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer If you choose to use a computer running Microsoft Internet Explorer or any of the Bosch software the computer must conform to the following minimum requirements Operating System Windows XP Service Pack 3 or Windows 7 32 or 64 bits Processor Intel Pentium...

Страница 82: ... identifier for the camera on a TCP IP network For example 140 10 2 110 is a valid syntax for an IP address Subnet mask A mask used to determine what subnet an IP address belongs to Gateway IP address A node on a network that serves as an entrance to another network Port An endpoint to a logical connection in TCP IP and UDP networks The port number identifies the use of the port for use through a ...

Страница 83: ...ce Click the Help on this page link if you need more information About the Configuration Page The Configuration page is used to configure the unit and the application interface Navigation 1 Click one of the menu items in the left window margin The corresponding submenu is displayed 2 Click one of the entries in the submenu The web browser opens the corresponding page Making Changes Each configurat...

Страница 84: ...he Audio page appears The page displays the current video image in the small window next to the slide controls to help you verify the audio source and to improve the Peak levels 4 Select the protocol in the Audio field to activate audio over IP Change the option to ON Notice The audio signal is sent in a separate data stream parallel to the video data and so increases the network load The audio da...

Страница 85: ... close Camera ID Each device should be assigned a unique identifier that can be entered here as an additional means of identification Initiator extension Add text to an initiator name to make identification easier in large iSCSI systems This text is added to the initiator name separated from it by a full stop You can see the initiator name in the System Overview page 17 2 User Management A passwor...

Страница 86: ...only possible to identify and correctly evaluate simultaneous recordings when all units are operating on the same time 1 Enter the current date Since the unit time is controlled by the internal clock there is no need to enter the day of the week it is added automatically 2 Enter the current time or click the Sync to PC button to copy your computer s system time to the camera Note It is important t...

Страница 87: ...pplications and subsequent function extensions Select Time server for a time server that works with the protocol RFC 868 17 4 Display Stamping Various overlays or stamps in the video image provide important supplementary information These overlays can be enabled individually and are arranged on the image in a clear manner After you set all necessary parameters click the View Control link to see ho...

Страница 88: ...tinuously display sector or shot title overlays in the image Select Momentary to display sector or shot title overlays for a few seconds OSD titles can be displayed at a position of your choice or it can be set to Off for no overlay information 1 Select the desired option from the list 2 Specify the exact position Position XY 3 In the Position XY fields enter the values for the desired position Ca...

Страница 89: ...meters on this page in accordance with the GB T 28181 national standard H 264 elementary stream Select this checkbox to select or to enable the H 264 elementary stream Registration timeout Enter a value in milliseconds for the registration timeout The default is 3600 Heartbeat timeout Enter the value in seconds for the heartbeat timeout The default is 15 Server ID Enter the ID of the server Server...

Страница 90: ...er in the local network or at an Internet address Device logo Enter the path to a suitable graphic if you want to replace the product name The image file can be stored on a local computer in the local network or at an Internet address Notice If you want to use the original graphics again simply delete the entries in the Company logo and Device logo fields Show VCA metadata When video content analy...

Страница 91: ...es color Show alarm outputs Alarm outputs are shown next to the video image as icons along with their assigned names If the alarm output is active the corresponding icon changes color Allow snapshots Here you can specify whether the icon for saving individual images snapshots should be displayed below the live image Individual images can only be saved if this icon is visible Allow local recording ...

Страница 92: ...ment for example network structure bandwidth data load To this end the camera simultaneously generates two data streams Dual Streaming which compression settings you can select individually for example one setting for transmissions to the Internet and one for LAN connections Pre programmed profiles are available each giving priority to different perspectives You can change individual parameter val...

Страница 93: ...or encoding on a 3G uplink where bit rate limitations are critical If required enter a new name for the profile Target bit rate To optimize use of the bandwidth in the network limit the data rate for the device The target data rate should be set according to the desired picture quality for typical scenes with no excessive motion For complex images or frequent changes of image content due to freque...

Страница 94: ...the image quality for every frame The lower the quantization of the P frame QP value the higher the encoding quality and thus the best image quality and the lower the frame refresh rate depending on the settings for the maximum data rate under network settings A higher quantization value results in low image quality and lower network load Typical QP values are between 18 and 30 The basic setting A...

Страница 95: ...ble options in the field Property for Stream 2 depending on the options selected for Stream 1 Note In order to select the option H 264 MP 720p50 60 fixed here you must first set the field Max frame rate in Camera Installer Menu to 50 60 fps up to 1280 x 720 px When the option in field Property for Stream 1 is The available options in field Property for Stream 2 are H 264 MP SD H 264 MP SD H 264 MP...

Страница 96: ...link where bit rate limitations are critical Note Non recording profiles streams are I frame only JPEG stream Select the resolution frame rate and image quality parameters for the M JPEG stream Resolution Select the appropriate resolution Max frame rate Select one of the following frame rates to be the maximum 5 10 15 20 25 30 or 60 fps Picture quality This setting allows you to adjust the image q...

Страница 97: ...ut a specific area of a scene from being viewed Masks can be configured as a gray area with four corners You may define a total of 24 privacy masks Pattern Select the color of the mask as it will appear in live video Gray Privacy mask Select the number of the privacy mask A colored rectangle appears in the unlabeled video preview window above the Set button 3 Navigate to the scene where the privac...

Страница 98: ...ring traffic or fast moving objects Low light Optimized performance for scenes with low light level Indoor Optimized for scenes with indoor lighting and avoids the limitations imposed by the sun or street lighting Vibrant Provides enhanced contrast color reproduction and sharpness The default setting depends on whether the camera is an in ceiling camera or a pendant camera Customize the mode if ne...

Страница 99: ...oise Reduction DNR which reduces noise based on motion and light levels Gain control Adjusts the automatic gain control AGC AGC default Automatically adjusts the gain to the lowest possible value needed to maintain a good picture Fixed no enhancement This setting disables the Max Gain Level option Fixed Gain Use the slide to select the desired number for fixed gain The default is 2 Maximum Gain Le...

Страница 100: ...pensates for the movement of the image by up to 2 of the image size This feature is ideal for cameras mounted on a pole or mast or on another location that shakes frequently On Stabilization is always on Off Stabilization is disabled Auto Stabilization activates automatically when the camera detects vibration greater than the set threshold Note This feature is not available on 20x models High dyna...

Страница 101: ... are On Off default Auto iris Automatically adjusts the lens to allow the correct illumination of the camera sensor This type of lens is recommended for use where there are low light or changing light conditions Constant default camera constantly adjusts to varying light conditions default If you select this option the camera makes the following changes automatically Gain Control switches to AGC S...

Страница 102: ...eeze the image while the camera moves to a predetermined scene position Turbo mode Select On to set the camera in Turbo mode when an operator pans or tilts the camera manually In this mode the camera can pan at a maximum of 400 per second and tilt at a maximum of 300 per second Azimuth Select On to display azimuth elevation readings Select Off to hide azimuth elevation readings Max PT speed Sets t...

Страница 103: ... to save all actions Compass The camera allows a user to display the compass heading of the camera in the lower right corner of the image display The camera displays the cardinal or intercardinal N NE E SE S SW W NW heading in which the camera is pointing Notice The compass feature is not compatible with Bosch s Intelligent Tracking feature If Intelligent Tracking is activated the camera automatic...

Страница 104: ... the preposition in the list and uncheck the box Include in standard tour marked with 3 Select a dwell time from the drop down list Standard preposition tour 4 To start the preposition tour Return to the Live page Click AUX Control Type 8 in the input box and click AUX on 5 To stop the tour type 8 and click AUX off Notice Refer to the document AUTODOME_OperationGuidelines_2014 pdf for guidelines f...

Страница 105: ... Stabilization auto Stabilization on Stabilization off WDR auto WDR on WDR off Night mode auto Night mode on Night mode off Gamma mode on Gamma mode off Gamma mode smart 1 Gamma mode smart 2 Gamma mode smart 3 IR focus correction on IR focus correction off OSD feedback on OSD feedback off IR mode on IR mode off IR mode auto Visible light on Visible light off Visible light inhibit on Visible light ...

Страница 106: ...era 19 13 Audio Audio You can set the gain of the audio signals to suit your specific requirements The live video image is shown in the window to help you check the audio source Your changes are effective immediately If you connect via Web browser you must activate the audio transmission on the Live functions page For other connections the transmission depends on the audio settings of the respecti...

Страница 107: ...ou can check whether the requirements for specific functions for example identification tasks are fulfilled 1 Click Freeze to freeze the camera image if the object that you want to measure is moving 2 To reposition a zone place the cursor over the zone hold down the mouse button and drag into position 3 To change the shape of a zone place the cursor over the edge of the zone hold down the mouse bu...

Страница 108: ... 2 Recording media Select a media tab to connect to the available storage media iSCSI Media To use an iSCSI system as the storage medium a connection to the desired iSCSI system is required to set the configuration parameters The storage system selected must be available on the network and completely set up It must have an IP address and be divided into logical drives LUNs 1 Enter the IP address o...

Страница 109: ... the storage medium 4 Click OK to close the window 20 1 5 Deactivating storage media A storage medium in the Managed storage media list can be deactivated It is then no longer used for recordings 1 Click a storage medium in the Managed storage media list to select it 2 Click Remove below the list The storage medium is deactivated and removed from the list 20 2 Recording Profiles A recording profil...

Страница 110: ...during the set post alarm time If you select Off no automatic recording takes place Caution You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time see Retention Time Stream Select the stream to be used for standard recordings Stream 1 Stream 2 I frames only Alarm recording Pre alarm time You can select the required pre alarm time from the ...

Страница 111: ...to other days with dates that fall on varying weekdays 1 Click the profile you want to link in the Time periods field 2 Click in a field in the table hold down the mouse button and drag the cursor over all the periods to be assigned to the selected profile 3 Use the right mouse button to deselect any of the intervals 4 Click the Select All button to link all time intervals to the selected profile ...

Страница 112: ...he Recording Profiles and Recording Scheduler pages are deactivated and the configuration cannot be modified You can stop the recording activity at any time and modify the settings 1 Click the Start button to activate the recording scheduler 2 Click the Stop button to deactivate the recording scheduler Running recordings are interrupted and the configuration can be changed Recording status The gra...

Страница 113: ...ding IP address for the desired remote station Destination password If the remote station is password protected enter the password here In this page you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations If connections to more than ten remote stations are to be possible for example when initiating connections via higher ranking system...

Страница 114: ...lect a particular video output and a split image is set for this output on the receiver you can also select from Decoder the decoder in the receiver that is to be used to display the alarm image Notice Refer to the destination unit documentation concerning image display options and available video outputs Decoder Select a decoder of the receiver to display the alarm image The decoder selected has ...

Страница 115: ...his can be useful if you want to test a number of different configurations Save a functioning configuration and test new settings You can use the saved configuration to restore the original settings at any time Notice If computing power becomes short the highest priority is always the live images and recordings This can lead to impairment of the video content analysis You should therefore observe ...

Страница 116: ...ters here directly You can find information on this in the relevant documents on the product CD supplied Metadata is always created for a video content analysis unless this was explicitly excluded Depending on the analysis type selected and the relevant configuration additional information overlays the video image in the preview window next to the parameter settings Options are MOTION IVA 5 6 IVA ...

Страница 117: ...due to continuous movement by a tree in the wind etc the relevant fields can be deactivated 4 Click Select Area to configure the sensor fields A new window will open 1 If necessary click Clear All first to clear the current selection fields marked yellow 2 Left click the fields to be activated Activated fields are marked yellow 3 If necessary click Select All to select the entire video frame for m...

Страница 118: ... if tampering associated with EMC interference noisy scene as the result of a strong interference signal in the vicinity of the video lines as an example should trigger an alarm Reference Check You can save a reference image that is continuously compared with the current video image If the current video image in the marked areas differs from the reference image an alarm is triggered This allows yo...

Страница 119: ...uld not be considered for flow analysis to trigger Intelligent Tracking This allows users to mask background motion in the scene such as moving trees pulsating lights busy roads etc To create a virtual mask 1 Select the number of the Virtual mask In the video preview window a dark grey rectangle appears with the text Mask x where x is the number of the mask 2 Select the mask with your mouse Move t...

Страница 120: ... mail In this way it is possible to notify a recipient who does not have a video receiver In this case the camera automatically sends an e mail to a previously defined e mail address Send alarm e mail Select On if you want the unit to automatically send an alarm e mail in the event of an alarm Mail server IP address Enter the IP address of a mail server that operates on the SMTP standard Simple Ma...

Страница 121: ...xamples link under the Alarm Task Editor field to see some script examples A new window will open 2 Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your requirements 3 When you are finished click the Set button to transmit the scripts to the unit If the transfer was successful the message Script successfully parsed is displayed over the text field If it was...

Страница 122: ... 00 00 Manipulation alarm If you select this option then an alarm will begin when the camera detects anyone manipulating it for example if the housing of the device is opened 4 Choose one of the following output commands for both Output 1 and Output 2 settings Note Not all options are available for all cameras None no defined command Alarm Output defines a physical connection from the open collect...

Страница 123: ...a filter option for quick search in recordings Enter a unique and clear name here Caution Do not use any special characters for example in the name Special characters are not supported by the system s internal management 22 2 Alarm Outputs Idle state Select Open if you want the relay to operate as an NO contact or select Closed if the relay is to operate as an NC contact Operating mode Select an o...

Страница 124: ...nt subnet enter the IP address of the gateway here Otherwise leave the box blank 0 0 0 0 IPv6 Consult with the network administrator before making changes to this section IP address Enter the desired IP address for the camera in this field The IP address must be valid for the network A typical IPv6 address may resemble the following example 2001 db8 52 1 1 Consult the network administrator for val...

Страница 125: ... Off option for each of the parameters HTTP browser port RCP port 1756 and Telnet support This deactivates all unsecured connections Connections will then only be possible via the HTTPS port You can activate and configure encryption of the media data video and metadata on the Encryption page see Encryption HSTS Select this option to use the web security policy HTTP Strict Transport Security HSTS t...

Страница 126: ...ns org Select another option as necessary Host name Enter the host name registered on DynDNS org for the camera here User name Enter the user name you registered at DynDNS org here Password Enter the password you registered at DynDNS org here Force registration now You can force the registration by transferring the IP address to the DynDNS server Entries that change frequently are not provided in ...

Страница 127: ...or TCP communication Select Off to deactivate the TCP metadata function Sender IP address Enter the IP address of the TCP metadata sender here 23 4 Network Management SNMP The camera supports the SNMP V1 Simple Network Management Protocol for managing and monitoring network components and can send SNMP messages traps to IP addresses The unit supports SNMP MIB II in the unified code If you wish to ...

Страница 128: ...der and a single receiver unicast the camera can enable multiple receivers to receive the video signal from an encoder simultaneously The device either duplicates the data stream itself and then distributes it to multiple receivers Multi unicast or it sends a single data stream to the network where the data stream is simultaneously distributed to multiple receivers in a defined group Multicast You...

Страница 129: ... greater than one if multicast is to be run via a router 23 6 Image Posting You can save individual JPEG images on an FTP server at specific intervals You can then retrieve these images at a later date to reconstruct alarm events if required In order to configure image posting and to save and retrieve JPEG images you must create an Account in which to save and access them If you have not configure...

Страница 130: ...s for the saved images For automatic width selection use value 0 23 7 Accounts Four separate accounts can be defined for posting and recording export Type Select either FTP or Dropbox for the account type Before using a Dropbox account ensure that the time settings of the device have been correctly synchronized Account name Enter an account name to be shown as the target name IP address Enter the ...

Страница 131: ...AUTODOME IP starlight 7000 HD Network en 131 Bosch Security Systems Operation Manual 2016 07 1 0 F 01U 283 679 Mask 1 2 Enter the subnet mask for the appropriate IPv4 address ...

Страница 132: ...n the device no longer being addressable requiring it to be replaced Progress The progress bar displays the progress of the firmware upload Note Once the progress bar reaches 100 a reset page may appear If this page appears allow the reset page to complete its action Upload history Click Show to view the firmware upload history Configuration Click Choose File to navigate to the required firmware f...

Страница 133: ... the plus sign To delete a certificate click the trashcan icon to the right of the certificate Note You can delete only certificates that you have added you cannot delete the default certificate File list Add a certificate file to the file list 1 Click Add The Add certificate window appears 2 Click Choose File to navigate to the required file 3 Click Upload Delete a certificate from the file list ...

Страница 134: ...Service AUTODOME IP starlight 7000 HD 2016 07 1 0 F 01U 283 679 Operation Manual Bosch Security Systems Select the text on this page with a mouse and copy it so that it can be pasted into an e mail if required ...

Страница 135: ...ick and hold the up or down arrows to tilt 2 Click and hold the left or right arrows to pan 3 Click and hold the center area to control both Move the mouse cursor over the video image additional options for controlling peripherals are displayed with the mouse cursor Click to focus near Click to focus far 25 1 3 Prepositions The camera displays Preposition 1 through Preposition 6 Select the appropr...

Страница 136: ...mation and indicates the status of an alarm input Active 1 Symbol lights Active 0 Symbol not lit The camera alarm output allows the operation of an external device for example a light or a door opener 4 To operate click the relay symbol The symbol is red when the output is activated 25 1 7 Special Functions Scan 360 Click this button to start a continuous 360 pan To stop the continuous pan click a...

Страница 137: ...e on the camera The OSD displays the message OSD Camera number Auto Focus ONE PUSH Custom tour Click this button to view a custom tour that was previously configured 25 1 9 Special Functions Scan 360 Click this button to start a continuous 360 pan To stop the continuous pan click a directional control in the View Control tab Autopan Click this button to pan the camera between user defined limits T...

Страница 138: ... 25 1 13 Full screen display Click the full screen icon to view the selected stream in full screen mode press Esc on the keyboard to return to the normal viewing window 25 1 14 Audio communication Audio can be sent and received via the Live page if the unit and the computer support audio 1 Press and hold the F12 key on the keyboard to send an audio signal to the unit 2 Release the key to stop send...

Страница 139: ... the Time lapse drop down box select the original or a condensed speed 4 In the Location drop down box select a target 5 Click Export to save the video track Note The target server address is set on the Network Accounts page 25 2 4 Controlling playback The time bar below the video image allows quick orientation The time interval associated with the sequence is displayed in the bar in gray Arrows i...

Страница 140: ...e the Intelligent Tracking feature one of the following conditions must be met The Silent IVA option must be selected in the VCA page on the Settings tab Refer to VCA page 115 IVA must be active for at least one preset scene in the VCA page on the Settings tab If IVA is configured for one scene then all other scenes have Intelligent Tracking enabled by default If a scene has Motion of IVA Flow act...

Страница 141: ...ng an object and a user takes control the camera will attempt to track the object after a period of inactivity An IVA alarm can trigger Intelligent Tracking to track a detected object A rule that triggers an IVA event must be set The following standard tasks can be set Object in field Crossing Line Loitering Condition change Following route Entering field and Leaving field Refer to the IVA 5 60 Op...

Страница 142: ... objects of interest without getting distracted by other moving objects in the scene To activate this mode you must enable IVA by selecting either IVA number or IVA number Flow in the field Analysis type of the page VCA from the page Configuration select Alarm VCA Refer to the current Operation Manual for IVA Intelligent Video Analysis for specific information If the option Show VCA metadata is se...

Страница 143: ...trol the level of moisture inside the camera Removing the bubble from the dome exposes the desiccant to moisture that could negatively affect the performance of the camera If you must remove the bubble for example to install or remove an SD card do not leave the bubble off of the dome for longer than five minutes Bosch also recommends that you keep the dome camera in its packaging until you are re...

Страница 144: ... the SD card Bosch recommends that you frequently check the recording status of your equipment Periodic replacement of the SD card may be required It is recommended that redundant recording systems are considered and that information is always backed up As with all storage media the lifetime of an SD card varies by supplier and use conditions The lifetime of a SD card is normally dependent on the ...

Страница 145: ...ine lock synchronization mode cannot be used Set the synchronization mode to INT NTSC Model power frequency in LL mode 60 Hz No video Check that the mains power to the power supply is on Check to see if you have a web page If you do not then you may have the wrong IP address Use Configuration Manager to identify the correct IP address If O K then Check that there is 24 V output from the transforme...

Страница 146: ...f O K then Contact Bosch Technical Support Loss of Privacy when using Privacy Mask Web browsers BVC or BVMS Press the FindHome key on the Special Functions menu in order to align the mask back to the original position Intuikey when keyboard is connected to BVC or BVMS Issue a SetScene 110 command in order to align the mask back to the original position No Network Connection Check all network conne...

Страница 147: ...kes the bubble brittle Cleaning the Bubble Exterior The exterior of the bubble is hard coated for extra protection If cleaning becomes necessary only use cleaning solutions and cloths suitable for cleaning safety glass lenses Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots Never scrub the bubble with any abrasive material or cleaners Bosch recommends cleaning the exte...

Страница 148: ... 283 679 Operation Manual Bosch Security Systems 29 Technical data For product specifications see the datasheets for AUTODOME IP 7000 Series and for AUTODOME HD 7000 Series available on the appropriate product pages of the Online Product Catalog at www boschsecurity com ...

Страница 149: ...able only with the AUTODOME 7000 IP Y On Off 40 Restore Camera Settings Restores all setting to their original defaults Y Y On Off 43 Auto Gain Control AGC On Auto Off 50 Playback Tour A Activate Deactivate 52 Playback Tour B Activate Deactivate Y On Off 57 Night Mode setting Enables Disables Night Mode Day Night only Y Y On Off 60 On Screen Display On enable Off disable Y Y On Off 66 Display Soft...

Страница 150: ... On Off 95 Display Azimuth Elevation Readings On Displays azimuth elevation readings Off Hides azimuth elevation readings On Off 96 Display Compass Heading On Displays compass heading Off Hides compass heading On Off 100 Record Tour A On start recording Off stop recording On Off 101 Record Tour B On start recording Off stop recording On Off 149 Turbo mode On activates turbo mode Off deactivates tu...

Страница 151: ......

Страница 152: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2016 Bosch Security Systems Inc 1706 Hempstead Road Lancaster PA 17601 USA ...

Отзывы: