Audio, Alarms and Relay Connections | en
57
Bosch Security Systems, Inc.
Installation Manual
F.01U.265.806 | 1.0 | 2012.03
9.2
Connecting Alarms (inputs 1 through 2)
You can configure alarms 1 through 2 as Normally Open (N.O.)
or Normally Closed (N.C.) alarms.
9.2.1
Connecting a Normally Open Alarm
1.
Connect the alarm to the appropriate input (1 through 2)
and ground at the HD Conference Dome.
Figure 9.2
N.O. - Normally Open
2.
From the HD Conference Dome Settings page select
Interface>Alarm Inputs. Refer to
Section 12 Configuring the
HD Conference Dome, page 80
, for directions about
accessing the Settings page.
Ref. # User Contact Dome
Color
1
Normally
Open
Alarm In 1 or Alarm In 2
(Ref. #3)
Brown IN 1 or
Orange IN 2
2
Common
Ground (Ref. #4)
Green
HD Conference Dome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm