background image

The JA-80PB wireless motion/glass-break detector 

 

MHP52507 

The JA-80PB wireless PIR motion/glass-break detector 

The JA-80PB is a component of Jablotron’s Oasis alarm system. It consists 

of two independent detectors which occupy two separate enrollment 

addresses in the control panel. The motion detector uses a PIR sensor. The 

glass-break detector uses the analysis of air pressure variations combined with 

the characteristic sound of glass breaking. The product is designed for internal 

use in buildings. The battery-powered detector communicates via OASIS radio 

protocol.

 

 

 

PIR movement detector 

 

 

 

Glass-break detector 

Installation 

Installation shall only be undertaken by technicians holding a certificate 

issued by an authorized distributor. The detector can be installed on a flat wall 

or in the corner of a room. Within the detection range of the PIR sensor avoid 

the presence of objects rapidly changing in temperature, such as electrical 

heaters, gas appliances etc. Moving objects with a temperature close to that of 

humans such as curtains moving above a radiator, and  pets should also be 

avoided. Detectors should not face windows or spotlights or be near fast-

moving air e.g. near ventilation fans or open windows or doors. Because of its 

sensitivity to air pressure changes and sounds it should not be located close to 

air conditioning or ventilation outlets. There should be no sources of vibration 

or audible sounds in the protected area. There should also be no obstacles 

blocking the detector’s “view” of the protected area. Keep the detector away 

from metal objects which could interfere with radio communication. 

Warning: The most frequent cause of false alarms is bad detector-

positioning 

Do not arm this detector if there are any people or pets moving within the 

protected area. 

1.  Open the detector 

cover by pressing the tab and disconnect the cable to 

the module located in the front cover.

 

2.  Remove the internal PIR module 

held by an internal tab.

 

3. 

Punch screw holes through the rear plastic cover. 

At least one screw 

should penetrate the tamper-sensitive section. 

4. 

Screw the rear cover to the wall, 

about 2 metres above the floor 

(vertically, with the tab down). 

5. 

Return the PIR module 

to its original place. 

6. 

Leave the cover open 

and then follow the control panel or receiver 

manual. The basics of enrollment are: 
a.  Enter enrollment mode on the control panel by keying in “1” in Service 

mode. 

b.  Install a battery in the PIR detector to activate its enrollment. 
c.  Install a battery in the glass-break detector and then connect its cable 

to the PIR module. This will activate its enrollment to the next vacant 

address in the control panel. This means that the glass-break detector 

enrolls after the PIR does. 

d.  Exit enrollment mode by pressing “#” 

To observe EN 50131-2-2 the tab must be secured by the supplied screw.

 

To enroll a detector after having already connected batteries, first disconnect 

the batteries, and press and release the tamper sensor to discharge any 

remaining charge to ready the device for enrollment. After installing batteries 

into the detector, allow two minutes for stabilisation. During this period the LED 

is continuously lit.

  

PIR module DIP switches 

NORM / HIGH: 

selection of 

immunity to false alarms

. The NORM position 

combines very good immunity with fast sensor reactions. The HIGH position 

gives increased immunity with a slower reaction time and is only used for 

problematic installations. 

INS / DEL

. DEL provides entrance & exit delays for detectors installed in a 

building entrance.  INS allows the detector to instantly trigger alarm activation 

if the control panel is armed. This DIP switch (INS/DEL) only has an effect if 

the detector has a 

natural reaction assigned

  to its address in the Oasis 

control panel. It also has no effect when used with a UC-8x or AC-8x receiver.

 

 

 

 

Glass-break module DIP switches 

DEL / INS 

selects the 

reaction of the control panel

  if glass-breaking is 

detected. DEL provides entrance & exit delays  and is recommended for 

detectors installed near a building’s entrance door.

 

INS allows the detector to 

instantly trigger alarm activation if the control panel is armed. This DIP switch 

(INS/DEL) only has an effect if the detector has a 

natural reaction

 assigned to 

its address in the Oasis control panel. It also has no effect when used with a 

UC-8x or AC-8x receiver.

 

PIR / GBS: 

This selects whether PIR or glass-break triggering is shown by 

the LED. Changing this setting only has an effect during the first 15 minutes 

after closing the cover (test mode). 

Note: Although both detectors are located in one housing, they do act 

independently. Each one has its own address. Each one also has its own 

selectable reaction via DIP switches in the detector or in SERVICE mode on 

the control panel. 

Testing the detector  

15 minutes after closing the detector cover, the LED shows PIR or glass-beak 

detector triggering according to what was previously selected by the PIR/GBS DIP 

switch during test mode. The strength and quality of detector signals can be 

measured by the control panel in Service mode.   

With the DIP switch in

 position PIR, 

short LED flashes indicate the processing of 

movement triggering the detector. Long flashes show that movement detection is 

being signalled to the control panel.  

With the DIP switch in

  position GBS, 

the LED flashes very briefly when air 

pressure changes occur, e.g. a soft knock on a window. A long flash indicates 

triggering by breaking glass and the transmission of a signal to the control panel. 

Testing and adjusting the glass-break sensor: 

  Using a suitable tool or a hand protected by gloves, one by one, knock all 

the windows that should be under the detector’s protection. A visible 

deformation of the glass should occur but without any damage. 

  The deformation of glass causes a change in the air pressure of the room 

which makes the LED on the detector flash quickly. The DIP switch must 

be in the GBS position. 

  Sensitivity to air pressure changes can be adjusted by a potentiometer on 

the glass-break sensor PCB located inside the front cover of the detector. 

Turning clockwise increases sensitivity. Avoid selecting too high a 

sensitivity as this can cause a short battery lifetime. 

  The complete function of the glass-break detector can be tested with a 

GBT-212 glass-break simulator. After knocking the glass, this simulator 

will automatically generate the characteristic sound of breaking glass to 

create the conditions for detector triggering. 

 

If there are any devices in the detector’s protected area generating sound 

such as air conditioning, heating, fax machines, refrigerators, etc., check 

that they are not triggering alarms by emitting sounds like breaking glass.

  

Отзывы: