122
en | Configuring the HD Conference Dome
HD Conference Dome
F.01U.265.806 | 1.0 | 2012.03
Installation Manual
Bosch Security Systems, Inc.
addresses to which the HD Conference Dome will connect in
sequence in the event of an alarm, until a connection is made.
Connect on alarm
Select
On
so that the HD Conference Dome automatically
connects to a predefined IP address in the event of an alarm.
By setting
Follows input 1
the unit maintains the connection
that has been automatically established for as long as an alarm
exists on alarm input 1.
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the
event of an alarm. The unit contacts the remote stations one
after the other in the numbered sequence until a connection is
made.
Destination IP address
For each number, enter the corresponding IP address for the
desired remote station.
Destination password
If the remote station is password protected, enter the
password here.
In this page, you can save a maximum of ten destination IP
addresses and hence up to ten passwords for connecting to
remote stations. If connections to more than ten remote
stations are to be possible, for example when initiating
connections via higher-ranking systems such as VIDOS or Bosch
Video Management System, you can store a general password
here. The HD Conference Dome can use this general password
to connect to all remote stations protected with the same
password. In this case, proceed as follows:
1.
Select
10
from the
Number of destination IP address
list
field.
NOTICE!
In the default setting, Stream 2 is transmitted for alarm
connections. Bear this fact in mind when assigning the profile
(see
Section 12.19 Encoder Profile, page 97
).